ACCU-TOUCH Touch-Screen Thermometer & Timer
ITEM#: THM-309-90 / THM-309-95
USE & CARE INSTRUCTIONS
IMPORTANT: RETAIN FOR FUTURE REFERENCE, READ CAREFULLY.
For assistance with use, parts and customer service call +1(203)888-9208 Monday through Friday, 9AM to 5PM EST,
email [email protected] or visit our website at www.polder.com.
Customers in the UK can call +44 (0) 1243 780501 or visit www.polderproducts.co.uk
IMPORTANT INFORMATION:
If this is your first time using the Accu-Touch Touch-Screen Thermometer & Timer please be sure to remove the protective insulation tape from the battery compartment and
protective sheet from the LCD screen before use.
TO INSTALL / CHANGE BATTERY
Warning: batteries may pose a choking hazard. Do not let children handle batteries.
This item uses two AAA batteries. In order to ensure proper performance, be sure to replace batteries as a simultaneous set. Batteries should be removed from the timer if
consumed or if the product is to be left unused for a duration of time. It is recommended to clean all battery contacts prior to installation. Do not mix old and new batteries.
Do not mix alkaline, standard (Carbon-Zinc), or rechargeable (Nickel Cadmium) batteries.
Always purchase the correct size and grade of battery most suitable for the intended use.
Replace all batteries of a set at the same time.
Ensure all batteries are installed correctly with regard to polarity (+ and -).
Remove used batteries promptly.
1. Battery door is located on the back of the unit.
2. Press and lift open the battery cover to remove.
3. Insert two AAA size batteries as indicated by the polarity symbols (+ and -).
4. Replace battery door, sliding back onto the unit until it snaps in place.
DISPOSAL OF USED BATTERIES
.
Batteries may contain hazardous substances which could endanger the environment and human health. This symbol marked on the battery and/or packaging
v j i
indicates that used battery shall not be treated as municipal waste. Instead it shall be left at the appropriate collection point for recycling. By ensuring the used
\ b a t t e r i e s are disposed of correctly, you will help prevent potential negative consequences for the environment and human health. The recycling of
/ \ —© y
materials will help conserve natural resources. For more information about collection and recycling of used batteries, please contact your local municipality, your
waste disposal service or the point of sale where you purchased this product.
TO USE THE THERMOMETER FUNCTION:
There is a switch located on the back of the unit. Move the switch to the COOK position.
TO READ IN FAHRENHEIT OR CELSIUS DEGREES:
While in thermometer (COOK) mode, briefly tap the (S/S) button to switch between Fahrenheit and Celsius degrees.
NOTE TEMPERATURE RANGE: -40°F ~ 482°F (-40°C ~ 250°C)
GENERAL COOKING INSTRUCTIONS:
Be sure the oven is pre-heated to the appropriate temperature.
1. Push the (OFF - COOK - TIMER) switch located on the back of the unit to the COOK position.
2. Be sure the probe is securely plugged into the display unit. If "LLL" appears below COOK TEMP, the probe has not been plugged in properly.
3. Press (M/M) to select type of meat (Beef, Pork, Fish, Veal, Lamb, Chicken, Turkey, Hamburger and PGM)
PGM (programmable setting) can be set to the user's preferred temperature.
TO USE THE PGM FUNCTION
• Press (M/M) to select the open setting. 'PGM' will appear in the lower right hand corner of the upper (blue) screen.
• Press and hold (S/S) for 3 seconds until the digits under ALERT TEMP begin to flash.
• Press (M/M) to increase temperature and (T/S) to decrease temperature until your desired temperature has been reached,
to
scroll quickly simply maintain pressure on (M/M) or (T/S)
• Press (S/S) to confirm setting.
4. Once the meat type has been selected, press (T/S) to select desired degree of doneness. The preset temperature will display under ALERT TEMP.
5. Insert the tip of the probe into the center of the thickest part of the meat. Be careful not to let the probe touch any bones, very fatty areas or cooking
surfaces as this may cause an inaccurate reading.
6. When the meat reaches its preset temperature / doneness level, the thermometer will alert with beeps.
7. To silence the alert, simply press (M/M), (T/S) or (S/S) on the display screen.
NOTE: the backlighting displays for 10-seconds. Simply press any button on the touch-screen display to illuminate.
TO USE THE 100-MINUTE TIMER FUNCTION:
There is a switch located on the back of the unit. Move the switch to the TIMER position.
TO SET TIMER:
1. Press (M/M) until the desired minutes are reached. To scroll quickly, maintain pressure on (M/M).
2. Press (T/S) until the desired seconds are reached. To scroll quickly, maintain pressure on (T/S).
3. Press (S/S) to begin the timer function. Countdown will begin counting in seconds and can be paused and restarted by pressing (S/S).
4. When countdown is complete the alarm will sound for 30-seconds and the timer will return to the original time set.
TO RESET TIMER:
If the user has entered the wrong time or would like to use a different feature, reset the timer to 00:00 by pressing (M/M) and (T/S) at the same time.
NOTE: the backlighting displays for 10-seconds. Simply press either the (M/M) or (T/S) buttons to illuminate the display while timing.
POWER ON/OFF:
There is a switch located on the back of the unit. Move the switch to the OFF position. It is recommended to keep the switch in the OFF position while not in use.