1.56
9850045 R01 - 2020-2021 RANGER 1000 Service Manual
© Copyright Polaris Inc.
SPN
COMPONENT
FMI
CONDITION
CODE
520305
Throttle Body Control - Requested
Throttle Angle Not Plausible
31
Condition Exists
P1530
520306
ECU ADC Fault - No Load
31
Condition Exists
P1531
520307
ECU ADC Fault - Voltage
31
Condition Exists
P1532
520308
Accelerator Sensor Sync Fault -
Sensor Diff Exceeds Limit
31
Condition Exists
P1533
520309
ECU Fault - ICO
31
Condition Exists
P1534
520311
ECU Fault - Hardware Disruption
31
Condition Exists
P1537
520331
Knock Sensor Positive Line
3
Voltage Above Normal, Or Shorted To High Source
P1327
4
Voltage Below Normal, Or Shorted To Low Source
P1328
520332
Knock Sensor Negative Line
3
Voltage Above Normal, Or Shorted To High Source
P132A
4
Voltage Below Normal, Or Shorted To Low Source
P132B
520341
Wastegate Solenoid Driver
3
Voltage Above Normal, Or Shorted To High Source
P0243
4
Voltage Below Normal, Or Shorted To Low Source
P0246
5
Current Below Normal Or Open Circuit
P0245
520342
Idle Fuel Correction Bank 1
15
Data Valid But Above Normal Operating Range - Least Severe Level
P116C
520343
Idle Fuel Correction Bank 2
15
Data Valid But Above Normal Operating Range - Least Severe Level
P116E
17
Data Valid But Below Normal Operating Range - Least Severe Level
P116F
520344
Adaptive Fuel Correction Bank 1
15
Data Valid But Above Normal Operating Range - Least Severe Level
P0170
17
Data Valid But Below Normal Operating Range - Least Severe Level
P1170
520376
Internal fault - Chassis Output
Disabled
31
Condition Exists
P1618
520381
Non Functional Application SW
Installed
31
Condition Exists
C1681
520496
Intercooler Pump Driver Circuit
3
Voltage Above Normal, Or Shorted To High Source
P107D
4
Voltage Below Normal, Or Shorted To Low Source
P107C
5
Current Below Normal Or Open Circuit
P107E
520498
Stator
4
Voltage Below Normal, Or Shorted To Low Source
P1510
5
Current Below Normal Or Open Circuit
P1511
520513
Motor Controller Encoder
2
Data Erratic, Intermittent Or Incorrect
P1140 / P1368
31
Condition Exists
P1141 / P1369
520514
Motor Controller Temperature
Sensor
3
Voltage Above Normal, Or Shorted To High Source
P1142 / P1165
4
Voltage Below Normal, Or Shorted To Low Source
P1143 / P1166
31
Condition Exists
P1144 / P1167
520515
Electric Motor Temperature
0
Data Valid But Above Normal Operational Range - Most Severe Level
P1145 / P1168
4
Voltage Below Normal, Or Shorted To Low Source
P1B0D / P1169
520516
Motor Controller Temperature
0
Data Valid But Above Normal Operational Range - Most Severe Level
P1146 / P116A
520517
Motor Controller
3
Voltage Above Normal, Or Shorted To High Source
P1147 / P1184
6
Current Above Normal Or Grounded Circuit
P1148 / P1185
12
Bad Intelligent Device Or Component
P1149 / P1186
19
Received Network Data In Error
P1150 / P1187
520518
Motor Controller Contactor
5
Current Below Normal Or Open Circuit
P1151 / P1177
6
Current Above Normal Or Grounded Circuit
P1152 / P1178
520519
Motor Controller Speed Sensor
31
Condition Exists
P1153 / P116B
520520
BMC CAN Communication
31
Condition Exists
P0754
520522
Display Relay
5
Current Below Normal Or Open Circuit
P3038
524067
Drive Mode Select Switch
2
Data Erratic, Intermittent Or Incorrect
P153C
3
Voltage Above Normal, Or Shorted To High Source
P153A
4
Voltage Below Normal, Or Shorted To Low Source
P153B
524070
Operator Presence Switch
3
Voltage Above Normal, Or Shorted To High Source
P251C
Summary of Contents for RANGER 1000 2020