1.52
9850045 R01 - 2020-2021 RANGER 1000 Service Manual
© Copyright Polaris Inc.
SPN
COMPONENT
FMI
CONDITION
CODE
5
Current Below Normal Or Open Circuit
P0481
1809
Lateral Acceleration Sensor
13
Out Of Calibration
C1261
19
Received Network Data In Error
U25CA
20
Data Drifted High
C1161
1810
Longitudinal Acceleration Sensor
7
Mechanical System Not Responding Or Out Of Adjustment
C1362
13
Out Of Calibration
C1262
19
Received Network Data In Error
U25CB
20
Data Drifted High
C1162
1888
PTO Solenoid Driver Circuit
3
Voltage Above Normal, Or Shorted To High Source
P1311
4
Voltage Below Normal, Or Shorted To Low Source
P1312
5
Current Below Normal Or Open Circuit
P1310
2584
Brake Pressure Switches
3
Voltage Above Normal, Or Shorted To High Source
C2244
4
Voltage Below Normal, Or Shorted To Low Source
C2044
13
Out Of Calibration
C1263
17
Data Valid But Below Normal Operating Range - Least Severe Level
C2144
20
Data Drifted High
C1164
2590
Vehicle Speed
16
Data Valid But Above Normal Operating Range - Moderately Severe
Level
P1500
2596
Speed Key Selected Maximum
Vehicle Speed Limit Message
19
Received Network Data In Error
U255A
31
Condition Exists
U2259
2629
Engine Turbocharger 1
Compressor Outlet Temperature
3
Voltage Above Normal, Or Shorted To High Source
P1235
4
Voltage Below Normal, Or Shorted To Low Source
P1236
3056
Oxygen Sensor Bank 1 Sensor 1
2
Data Erratic, Intermittent Or Incorrect
P0130
3
Voltage Above Normal, Or Shorted To High Source
P0132
4
Voltage Below Normal, Or Shorted To Low Source
P0131 / C1049
12
Bad Intelligent Device Or Component
P113A
17
Data Valid But Below Normal Operating Range - Least Severe Level
C2049
3057
Oxygen Sensor Bank 1 Sensor 2
2
Data Erratic, Intermittent Or Incorrect
P0136
3
Voltage Above Normal, Or Shorted To High Source
P0138
4
Voltage Below Normal, Or Shorted To Low Source
P0137
3597
ECU Output Supply Voltage 1
0
Data Valid But Above Normal Operational Range - Most Severe Level
P16A3
1
Data Valid But Below Normal Operational Range - Most Severe Level
P16A6
3
Voltage Above Normal, Or Shorted To High Source
P16A2
4
Voltage Below Normal, Or Shorted To Low Source
P16A1
16
Data Valid But Above Normal Operating Range - Moderately Severe
Level
P16A5
18
Data Valid But Below Normal Operating Range - Moderately Severe
Level
P16A7
3598
ECU Output Supply Voltage 2
0
Data Valid But Above Normal Operational Range - Most Severe Level
P16AA
1
Data Valid But Below Normal Operational Range - Most Severe Level
P16AC
3
Voltage Above Normal, Or Shorted To High Source
P16A9
4
Voltage Below Normal, Or Shorted To Low Source
P16A8
16
Data Valid But Above Normal Operating Range - Moderately Severe
Level
P16AB
18
Data Valid But Below Normal Operating Range - Moderately Severe
Level
P16AD
3599
ECU Output Supply Voltage 3
0
Data Valid But Above Normal Operational Range - Most Severe Level
P17AC
1
Data Valid But Below Normal Operational Range - Most Severe Level
P17AE
3
Voltage Above Normal, Or Shorted To High Source
P17AA
4
Voltage Below Normal, Or Shorted To Low Source
P17AB
Summary of Contents for RANGER 1000 2020
Page 4: ...REVISION INDEX REV DATE CHANGES R01 11 06 2020 Initial release...
Page 6: ......
Page 8: ......
Page 308: ...5 28 9850045 R01 2020 2021 RANGER 1000 Service Manual Copyright Polaris Inc NOTES FUEL SYSTEM...
Page 374: ......