2.58
9850060 R02 - 2020-2021 850 AXYS™ Long Track Snowmobile Service Manual
© Copyright Polaris Inc.
9. Allow battery to stand for 1-2 hours before checking
voltage.
10. Check open circuit voltage. Continue charging as
needed.
Battery Open Circuit Voltage:
12.6 Volts
BATTERY TENDER PORT
NOTICE
The battery tender port is only applicable to MY20 to
current models.
To ensure the battery maintains its level of charge, the
battery should be connected to a battery tender/trickle
charger using the battery tender port
q
.
BATTERY OFF SEASON STORAGE
Whenever the vehicle is not used for a period of two
months or more, remove the battery from the vehicle,
ensure that it is fully charged, and store it out of the sun
in a cool, dry place. Check battery voltage each month
during storage and/or recharge as needed to maintain a
full charge.
NOTICE
Battery charge can be maintained by using a Polaris
battery tender charger or by charging once a month to
make up for normal discharge. Battery tenders can be
left connected during the storage period and will
automatically charge the battery if the voltage drops
below a pre-determined point.
CHASSIS GROUND
The chassis ground connection
q
is secured to the
inside of the front bumper by the left rear mounting
fastener.