PMC EL-51A Quick Start Manual Download Page 1

 

 

 

 

 

EL-51A-4 

 

TEMPERATURE 

SENSING 

UNIT 

 

 

Manual 

Ref. # MN-04016 

 

Revision 1.2

 

April 2, 2019

 

 

REVISION 1.2 

April 2, 2019 

Polyurethane Machinery Corp. 

Corporate

: 1 Komo Dr, Lakewood, NJ 08701  

Manufacturing

: 2 Komo Dr, Lakewood, NJ 

08701 

Phone

: 732-415-4400 

Fax

: 732-364-4025 

URL:

 http://www.polymacusa.com

 

Before  using  the  TSU,  carefully  read  all  the  technical  and  safety 
documentation  included  in  this  manual.  Pay  special  attention  to  the 
information  in  order  to  know  and  understand  the  operation  and  the 
conditions of use of the TSU. All of the information is aimed at improving 
user  safety  and  avoiding  possible  failures  from  the  incorrect  use  of  the 
TSU. 

 

Summary of Contents for EL-51A

Page 1: ...Phone 732 415 4400 Fax 732 364 4025 URL http www polymacusa com Before using the TSU carefully read all the technical and safety documentation included in this manual Pay special attention to the inf...

Page 2: ...i EL 51A 4 TABLE OF CONTENTS TABLE OF CONTENTS WARRANTY 1 SAFETY AND HANDLING 3 CHARACTERISTICS 5 TECHNICAL SPECIFICATIONS 5 DESCRIPTION 6 INSTALLATION 7 TROUBLESHOOTING 8 PARTS IDENTIFICATION 10 MANU...

Page 3: ...rial number The Warranty does not cover any Product if the Original Invoice appears to have been modified or altered or when the serial number on the Product appears to have been altered or defaced Pr...

Page 4: ...y for Products Repaired or Replaced under Warranty Following the repair or replacement of a Product covered by this Warranty such Product will continue to be subject to the original Warranty for the r...

Page 5: ...TION Presents information that indicates how to avoid damage to the Proportioner or how to avoid a situation that could cause minor injuries NOTE Is relevant information of a procedure being carried o...

Page 6: ...t possible injury caused by incorrect handling of the raw materials and solvents used in the process carefully read the Safety Data Sheet SDS provided by your supplier Deal with the waste caused accor...

Page 7: ...HARACTERISTICS Accurate and precise Compact design Easy to install Low maintenance TECHNICAL SPECIFICATIONS Thermocouple Type Type E Temperature Range 0 to 1000 o F 18 to 540 o C A Side Fittings 5 JIC...

Page 8: ...RIPTION DESCRIPTION A Thermocouple Connector B Flexible Metal Conduit C A Side Inlet Fitting D A Side Outlet Fitting E Sensing Wire F R Side Inlet Fitting G TSU Body H R Side Outlet Fitting I Air Inle...

Page 9: ...ly bend the Heated Hoses Do not coil the Heated Hoses with a diameter of less than 4 feet 1 22 meters Recommended order of connections 1 It is recommended that the TSU be installed between the last se...

Page 10: ...ding to current regulations To avoid damage caused by the impact of pressurized fluids do not open any connection or perform maintenance work on components subject to pressure until the pressure has b...

Page 11: ...tions AUBER EATON OMRON TC Terminal Purple Wire Terminal 7 Terminal 9 Terminal 12 TC Terminal Red Wire Terminal 6 Terminal 10 Terminal 11 If connections are secure move to the next step 2 Remove the t...

Page 12: ...2 1 EL 00051A 3 1 8 X 4 JIC FEM SWIVEL FTG 3 1 EL 00051A 4 1 4 X 5 JIC MALE FTG 4 1 EL 00051A 5 1 4 X 6 JIC FEMALE SWIVEL FTG 5 1 EL 00051A 6 1 4 X 6 JIC MALE FTG 6 1 EL 00051A 7 1 4 X 5 JIC FEMALE S...

Page 13: ...Revision Date Changes Approved 1 0 09 01 2015 Initial release of EL 51A 4 Manual Vadams 1 1 09 15 2017 Change position of the page number from bottom center to bottom right SS 1 2 04 02 2019 Updated...