0000111659/150418/B MobileGo
EN - 3
PREFaCE
using this manual
This manual is intended to be used as a work of reference for
professional, well trained and authorised users to be able to
safely install, use, maintain and repair the product mentioned
on the cover of this document.
Pictograms and symbols
The following pictograms and symbols are used in this manual:
TiP
Suggestions and recommendations to simplify
carrying out tasks and actions.
aTTENTioN
A remark with additional information for the user. A
remark brings possible problems to the user’s
attention.
CauTioN!
Procedures, if not carried out with the necessary
caution, could damage the product, the workshop or
the environment.
WaRNiNG!
Procedures which, if not carried out with the
necessary caution, may damage the product or
cause serious personal injury.
CauTioN!
Denotes risk of electric shock.
WaRNiNG!
Fire hazard! Important warning to prevent fire.
WaRNiNG!
Explosion hazard! Important warning to prevent
explosions.
Personal protective equipment (PPE)
Instruction to use respiratory protection when you
do service, maintenance and repair jobs, as well as
during functional testing. We recommend to use a
half-face respirator according to EN 149:2001 +
A1:2009, classe FFP3 (Directive 89/686/EEC).
Personal protective equipment (PPE)
Instruction to use protective gloves when you do
service, maintenance and repair jobs.
Text indicators
Listings indicated by “-” (hyphen) concern enumerations.
Listings indicated by “•” (bullet point) describe steps to
perform.
Service and technical support
For information about specific adjustments, maintenance or
repair jobs which are not dealt with in this manual, please
contact the supplier of the product. He will always be willing to
help you. Make sure you have the following specifications at
hand:
- product name
- serial number
You can find these data on the identification plate.
Product indications
Unless specifically stated, the contents of this manual applies
to the MobileGo
as well as the
MobileGo
plus
.
1
iNTRoDuCTioN
1.1
Identification of the product
The identification plate contains, among other things, the
following data:
- product name
- serial number
-
supply voltage and frequency
-
power consumption
1.2
General description
The MobileGo is a mobile filter unit with an integrated fan and
an extraction arm. It features a pre filter cassette and a HEPA
filter cassette (both disposable). Thanks to the four transport
wheels (two of which are swivel casters with brake), the
MobileGo is suitable to be used in relatively small facilities or
near sources of pollution without a fixed location.
1.2.1 Intensity of use
We recommend to use the MobileGo
for occasional welding
1
and TIG welding. The
MobileGo
plus
is suitable for occasional to
regular welding activities
2
.
1.3
Technical specifications
MobileGo
MobileGo
plus
Physical dimensions and properties
Material (housing)
electro-zinc coated steel
Weight (excl. arm)
84 kg (185 lbs)
85,5 kg (188.5 lbs)
Filters
Pre filter cassette:
- material
polyester
polyester
-
filter surface
1 m² (10.8 ft²)
1 m² (10.8 ft²)
-
filter classification
ISO Coarse 70%
according to ISO
16890
ISO Coarse 70%
according to ISO
16890
HEPA filter cassette:
- material
glass fibre
glass fibre
-
filter surface
15 m² (161 ft²)
26 m² (280 ft²)
-
efficiency class
E12 according to
EN 1822-1:2009
E12 according to
EN 1822-1:2009
Washable
no
no
Extraction arm
Type
hose tube arm
(EconomyArm)
metal tube arm
(KUA)
Length
2 or 3 m
2 or 3 m
Diameter
Ø 160 mm (6.3 in.) Ø 160 mm (6.3 in.)
Weight
Type
Weight
Type
Weight
EA-2
11 kg
(24.3 lbs)
KUA-2
12 kg
(26.5 lbs)
EA-3
13 kg
(28.7 lbs)
KUA-3 15,5 kg
(34.2 lbs)
Fan
Fan type
radial
Extraction capacity
max. 850 m�/h (500 CFM)
Fan speed
2800 rpm
Noise level
67
dB(A) according to ISO 3746
Electrical data
Power consumption
1,1 kW (1.5 HP)
Available connection
voltages
-
115V/1ph/50Hz
-
230V/1ph/50Hz
1.
approx. 1 coil of solid wire or 7,5 kg (16.5 lbs) of electrodes per month
2.
approx. 2 coils of solid wire or 15 kg (33 lbs) of electrodes per month