PEX 8618 Quick Start Hardware Design Guide – Version 1.2
Copyright © 2009 by PLX Technology, Inc. All rights reserved.
17
9 PEX 8618 Strapping Balls
The PEX 8618 has a total of 30 Strapping balls. Sixteen of them service different configuration functions. For the
PEX 8618, none of the Strapping balls, including the Strapping balls for configuration, have internal pull-up or pull-
down resistors. If the Port configuration is fixed, use external pull-up or pull-down resistors and hardwire these
Strapping balls to the values corresponding to the Port configuration desired. If a particular function is not used,
the related Strapping ball must pull up or pull-down to a known disabled logic state.
Table 3
lists the names and
functions of the PEX 8618 Strapping balls.
Table 3. Strapping Balls
Ball/Signal Name
Functions
STRAP_SERDES_MODE_EN#
Enable SerDes Mode Debug Function
STRAP_PROBE_MODE#
Enable Probe Mode Debug Function
STRAP_DEBUG_SEL0
Factory Test. Tied High.
STRAP_FAST_BRINGUP#
Factory Test. Tied High.
STRAP_RESERVED17#
Factory Test. Tied High.
STRAP_PLL_BYPASS#
Factory Test. Tied High.
STRAP_SSC_ISO_ENABLE#
Enable RefClk Isolation function.
STRAP_RESERVED16
Factory Test. Tied Low.
STRAP_NT_ENABLE#
Enable NT function
STRAP_NT_UPSTRM_PORTSEL0
NT Port select
STRAP_NT_UPSTRM_PORTSEL1
STRAP_NT_UPSTRM_PORTSEL2
STRAP_NT_UPSTRM_PORTSEL3
STRAP_PORTCFG0
Port configuration
STRAP_PORTCFG1
STRAP_PORTCFG2
STRAP_PORTCFG3
STRAP_TESTMODE0
Test mode function select
STRAP_TESTMODE1
STRAP_TESTMODE2
STRAP_TESTMODE3
STRAP_UPSTRM_PORTSEL0
Upstream Port select
STRAP_UPSTRM_PORTSEL1
STRAP_UPSTRM_PORTSEL2
STRAP_UPSTRM_PORTSEL3
STRAP_SPARE0#
Factory Test. Do not connect.
STRAP_SPARE1#
Factory Test. Tied High.
STRAP_NT_P2P_EN#
STRAP_SMBUS_EN#
STRAP_UPCFG_TIMER_EN#
Factory Test. Tied High.
STRAP_SPARE5#