BITalino R-IoT
User Manual
BR 20200207
15 of 42
5
R-IoT Configuration & Setup
5.1
Module Default Configuration
R-IoT
’s
default firmware implements a Wi-Fi Access Point (AP mode) and a Web server
(Station mode) to configure its wireless parameters such as the Wi-Fi network name
(SSID), the Open Sound Control UDP port to send data to the recipient computer IP
address.
The default SSID is "
riot
"; for a quick install, the simplest is to configure your router and
computer rather than edit the R-IoT configuration in first place.
By default, the module will be sending OSC data (
The OSC message structure is described in
) to the
DEST IP
(destination IP address)
192.168.1.100
on port
8888
. The
remaining data can be seen on Figure 3-4.
Figure 3-1
–
R-IoT Configuration.
5.2
Changing the Default Configuration
To trigger the configuration mode, press the
Mode button
while the R-IoT is turned off.
Then, turn the device on while holding down the mode button. The
RGB LED
will show a
red light that will flash rapidly, then turns green and finally it will turn and remain blue,
meaning that the device is in AP mode.
Figure 3-2
–
AP Mode details.
Mode Button
RGB LED