Plum eSTER x40 Installation And Operating Manual Download Page 4

 

1.

 

Recommendations regarding safety 

The following requirements shall be complied 
with. 

 

The  device  should  be  used  as  intended, 
keeping  it  in  a  dry  environment,  and 
installing it only indoors. 

 

The  thermostat  has  small  parts,  so  keep 
it away from children. 

 

Before  connecting  the  radio  module  to 
the  main  controller,  absolutely  stop  the 
operation  of  the  main  controller  by 
switching it off and disconnecting it from 
the main power supply. 

 

Non-compliant  with  the  manual  or 
incorrect  connection  of  the  radio  module 
to the main controller may be a source of 
malfunction  of  the  main  controller  and 
the radio module itself. 

 

The device should only be started up by a 
person  who  is  familiar  with  these 
instructions. 

 

Under  no  circumstances  may  the  device 
construction be modified. 

2.

 

General information 

Room thermostat eSTER_x40 is designed for 
wireless  cooperation  with  external  radio 
transmission  module  ISM_xSMART,  which  is 
wired to the main controller. The thermostat 
is  installed  in  a  selected  room,  eg  a  living 
room,  and  is  designed  to  maintain  a  preset 
room  temperature  by  sending  a  radio  signal 
to  a  module  connected  to  the  main 
controller. The  implemented  encrypted, two-
way  radio  communication  allows  the 
transmission  of  information  from  the  main 
controller  to  the  thermostat,  including  the 
fuel  level in  the  fuel  tank,  alarm  statuses  of 
the  regulator  and  external  temperature 
values.  The  thermostat  on  the  backlit  LCD 
display  shows  information  about  the  room 
temperature value, selected operating mode, 
current  time  with  simultaneous  clock 
synchronization with the main controller. 

 

Radio communication: 1 - eSTER_x40 thermostat, 
2  -  ISM_xSMART  radio  module,  3  -  main 
controller.

      

3.

 

Information about documentation 

The  thermostat  manual  is  a  supplement  for 
the  main  controller  manual.  In  particular, 
except  for  this  manual,  the  main  controller 
manual 

should 

also 

be 

followed. 

Manufacturer  is  not  responsible  for  any 
damages caused by failure to following these 
instructions. 

4.

 

Storage of documentation 

This assembly and operation manual, as well 
as  any  other  applicable  documentation, 
should  be  stored  diligently,  so  that  it  is 
available at any time. In the case of removal 
or  sale  of  the  device,  the  attached 
documentation should be handed over to the 
new user / owner. 

5.

 

Applied symbols 

In this manual the following graphic symbols 
are used: 

  -  the  symbol  indicates  additional 

advice and information. 

  -  the  symbol  indicates  important 

information. 
Caution:  the  symbols  indicate  important 
information,  in  order  to  make  the  manual 
more user friendly. Yet, this does not exempt 
the  user  from  the  obligation  to  comply  with 
requirements  which  are  not  marked  with  a 
graphic symbol! 

6.

 

Declaration of conformity 

The 

purchased 

product 

meets 

the 

requirements  of 

Directive  2014/53/EU  of 

the  European  Parliament  and  of  the 
Council  of  16  April  2014 

on  the 

harmonization  of  the  laws  of  the  Member 
States  concerning  making  available  on  the 
market  of  radio  equipment  and  does  not 
cause  harmful  interference  with  radio 
communications  to  other  equipment,  in  a 
residential area, provided that the product is 
correctly  installed  and  used  in  accordance 
with the requirements of this manual. 
The full text of the Declaration of Conformity 
is available at www.plum.pl in the Downloads 
section of the appliance website. 
 

Summary of Contents for eSTER x40

Page 1: ...L ISSUE 1 0 WIRELESS ROOM THERMOSTAT eSTER_x40 FOR HEATING CIRCUIT CONTROLLERS 04 2019 ISM_xSMART The ISM_xSMART radio module is standard equipment for the thermostat ONLY COOPERATES WITH THE ecoMAX S...

Page 2: ......

Page 3: ...10 12 SIGNALING OF THE ALARMS AND PROMPTS 10 12 1 ALARMS 10 12 2 PROMPTS 10 13 SETTINGS OF THE MAIN CONTROLLER PARAMETERS 10 14 INSTALLATION OF THE THERMOSTAT 11 14 1 INSERTING OR REPLACING THE BATTE...

Page 4: ...k synchronization with the main controller Radio communication 1 eSTER_x40 thermostat 2 ISM_xSMART radio module 3 main controller 3 Information about documentation The thermostat manual is a supplemen...

Page 5: ...the main controller automatically sets the clock in the thermostat The clock can also be set directly in the thermostat from the User menu P04 The change of time in the thermostat will also cause a c...

Page 6: ...ental lock unblocking occurs after holding the button for 5 seconds 10 Thermostat settings 9 1 Edition of the preset temperature Pressing or brings to the check edit of the preset temperature which st...

Page 7: ...Antifreeze the thermostat works with a constant preset temperature Antifreeze P07 which ensures protection against freezing of water in the heating circuit This mode is useful when there is no one in...

Page 8: ...ch means the interval 00 30 01 00 Use or buttons to move between intervals 48 intervals every 0 5 h For each interval the preset temperature Night or Day can be set The button assigns the night or day...

Page 9: ...duration of the Airing mode min P14 Time one time of the HUW charging h P15 Turning on on or off oFF sound of pressing the buttons P16 Turning on on or off oFF sound alarms At the oFF setting alarm n...

Page 10: ...er and the beep if P16 parameter is set to on The first press of the button silences the alarm sound With and buttons you can check successive alarm numbers if there are more of them at the same time...

Page 11: ...e as a free standing device in a room representative for a given heating circuit After choosing the place of assembly make sure that the selected location is free of excessive humidity and the ambient...

Page 12: ...nd connection of the radio module to the main controller The ISM_xSMART radio module should be mounted on a wall near the installation location of the main controller If the radio connection is poor t...

Page 13: ...controller requires pairing with a thermostat Until the pairing with the radio module on the thermostat screen is complete the and symbols are permanently displayed Pairing from the main controller me...

Page 14: ...adio connection with the thermostat in the main controller Information menu the thermostat will be visible as ecoSTER TOUCH with the given version of the software The pairing method with the P button...

Page 15: ...o install the thermostat take into account the obtained signal level in the selected location by observing the symbol on thermostat screen If the symbol is not displayed the radio connection with the...

Page 16: ...the module to the ecoMAX860P3 D3 1 radio module 2 main controller Connection of the module to the ecoMAX910R1 ecoMAX920P1 1 radio module 2 main controller It is not recommended to turn off the power s...

Page 17: ...conditions i e rain and sun rays and vibrations higher than typical during road transport Storage and transport temperature should not exceed 10 60 C 18 Description of possible faults Symptoms Tips Th...

Page 18: ...18...

Page 19: ...19...

Page 20: ...ul Wsp lna 19 Ignatki 16 001 Kleosin Poland plum plum pl www plum pl...