In order to place the thermostat on a 
flat surface, use a dedicated stand. 

 

14.1

 

Inserting or replacing the 

batteries in the thermostat 

To insert or replace the battery,  remove the 
back cover of the thermostat housing.  

 

When  inserting  the  batteries,  the 
battery  poles  have  to  be  positioned 
correctly. 

 

 

It  is  recommended  to  use  alkaline 
batteries  to  power  the  thermostat. 
The  thermostat's  working  time 
depends  on  the  quality  of  the 
batteries used. 

15.

 

Radio module 

15.1

 

Installation and connection of the 

radio module to the main 
controller 

The  ISM_xSMART  radio  module  should  be 
mounted  on  a  wall  near  the  installation 
location  of  the  main  controller.  If  the  radio 
connection is poor, try placing the module in 
other  places.  Moving  the  module  even  by  a 
few centimeters can affect the quality of the 
connection. 

 

Placing  a  radio  module  in  a  metal 
casing, eg a mounting box, a metal 
boiler  casing,  etc.,  will  dampen  the 
radio  signal  and  thus  interfere  with 
the operation of this module. 

The  radio  module  should  be  screwed  to  the 
wall  with  mounting  screws.  Access  to  holes 
for  assembly  screws  is  obtained  after 
unscrewing the cover of this module. 

Screw holes 
Assembly screw 

Summary of Contents for eSTER x40

Page 1: ...L ISSUE 1 0 WIRELESS ROOM THERMOSTAT eSTER_x40 FOR HEATING CIRCUIT CONTROLLERS 04 2019 ISM_xSMART The ISM_xSMART radio module is standard equipment for the thermostat ONLY COOPERATES WITH THE ecoMAX S...

Page 2: ......

Page 3: ...10 12 SIGNALING OF THE ALARMS AND PROMPTS 10 12 1 ALARMS 10 12 2 PROMPTS 10 13 SETTINGS OF THE MAIN CONTROLLER PARAMETERS 10 14 INSTALLATION OF THE THERMOSTAT 11 14 1 INSERTING OR REPLACING THE BATTE...

Page 4: ...k synchronization with the main controller Radio communication 1 eSTER_x40 thermostat 2 ISM_xSMART radio module 3 main controller 3 Information about documentation The thermostat manual is a supplemen...

Page 5: ...the main controller automatically sets the clock in the thermostat The clock can also be set directly in the thermostat from the User menu P04 The change of time in the thermostat will also cause a c...

Page 6: ...ental lock unblocking occurs after holding the button for 5 seconds 10 Thermostat settings 9 1 Edition of the preset temperature Pressing or brings to the check edit of the preset temperature which st...

Page 7: ...Antifreeze the thermostat works with a constant preset temperature Antifreeze P07 which ensures protection against freezing of water in the heating circuit This mode is useful when there is no one in...

Page 8: ...ch means the interval 00 30 01 00 Use or buttons to move between intervals 48 intervals every 0 5 h For each interval the preset temperature Night or Day can be set The button assigns the night or day...

Page 9: ...duration of the Airing mode min P14 Time one time of the HUW charging h P15 Turning on on or off oFF sound of pressing the buttons P16 Turning on on or off oFF sound alarms At the oFF setting alarm n...

Page 10: ...er and the beep if P16 parameter is set to on The first press of the button silences the alarm sound With and buttons you can check successive alarm numbers if there are more of them at the same time...

Page 11: ...e as a free standing device in a room representative for a given heating circuit After choosing the place of assembly make sure that the selected location is free of excessive humidity and the ambient...

Page 12: ...nd connection of the radio module to the main controller The ISM_xSMART radio module should be mounted on a wall near the installation location of the main controller If the radio connection is poor t...

Page 13: ...controller requires pairing with a thermostat Until the pairing with the radio module on the thermostat screen is complete the and symbols are permanently displayed Pairing from the main controller me...

Page 14: ...adio connection with the thermostat in the main controller Information menu the thermostat will be visible as ecoSTER TOUCH with the given version of the software The pairing method with the P button...

Page 15: ...o install the thermostat take into account the obtained signal level in the selected location by observing the symbol on thermostat screen If the symbol is not displayed the radio connection with the...

Page 16: ...the module to the ecoMAX860P3 D3 1 radio module 2 main controller Connection of the module to the ecoMAX910R1 ecoMAX920P1 1 radio module 2 main controller It is not recommended to turn off the power s...

Page 17: ...conditions i e rain and sun rays and vibrations higher than typical during road transport Storage and transport temperature should not exceed 10 60 C 18 Description of possible faults Symptoms Tips Th...

Page 18: ...18...

Page 19: ...19...

Page 20: ...ul Wsp lna 19 Ignatki 16 001 Kleosin Poland plum plum pl www plum pl...