15
OI remote control for Pluggit Avent
Englis
h
Hold down the bottom of button (1) for approx. 5 seconds
until BYP6 appears on the display (2).
The room ventilation unit cools for 6 hours and on the
display (3) the air ducts run in parallel.
After the time has expired, the room ventilation unit auto-
matically switches back to the last operating mode.
3.10. RESET FILTER ALARM
Thanks to the integrated filter the supplied outside air and
exhaust air is cleaned of dirt particles and soiling of the unit
is avoided.
If the room ventilation unit is operated without a filter, the
hygiene requirements are not met.
The filter alarm must be reset after each filter change.
The black triangles on display (1) show the remaining useful
life of the filter. If all triangles are completely black, the
display (1) flashes and the filters must be replaced.
1. Press the centre of button (2) to activate the operating
mode line. The current operating mode flashes.
2. Repeatedly press button (2) at the right until the
display (1) starts flashing.
The display (3) shows e.g. -25. This means that there are
25 days left until the filter change is due.
3. Press the bottom of button (2).
The preset interval value for the filter change flashes on
the display (3), e.g. 360.
4. Press top or bottom of button (2) until the desired in-
terval value for the filter change is reached.
5. Press centre of button (2).
The setting is saved.
3.11. SWITCHING ON/OFF INSTALLER MENU
In the installer menu, the following values and settings can
be displayed and adjusted:
•
Readout the software version of the room ventilation
unit, the remote control and the accessories
•
Readout rotational speed of the supply air ventilator
•
Readout rotational speed of the exhaust air ventilator
•
Readout set points of the preheating (accessory)
•
Adjust set points of the preheating (accessory)
•
Readout temperatures from T
min
and T
max
for the by-
pass (accessory)
•
Set temperatures from T
min
and T
max
for the bypass (ac-
cessory)
•
Set sensitivity of the humidity sensor (accessory)
•
Set sensitivity of the VOC sensor (accessory)
Note:
For further information on replacing the filters, please
refer to the operating and installation instructions of the
room ventilation unit.
Die Wohnraumlüftung
RH%
2
3
1
M+P-26A-0975
Die Wohnraumlüftung
RH%
1
M+P-26A-0976
Warning:
The installer menu must only be used by qualified
expert personnel, otherwise damage may result.
Die Wohnraumlüftung
RH%
3
2
1
M+P-26A-0977