![pleasant hearth OAK100 Manual Download Page 1](http://html1.mh-extra.com/html/pleasant-hearth/oak100/oak100_manual_1567506001.webp)
2019-01-14
80-11-164
OUTSIDE AIR KIT
MODEL # OAK100
TO BE USED WITH ALL PLEASANT HEARTH
UNIVERSAL FIREBOX MODELS
OUTSIDE AIR KIT ASSEMBLY
Insulation
Gasket x1
#8 x 3/8 Sheet
Metal Screws x4
#8 Wood Screws
(Not Included) x4
Starting
Collar x1
Inlet Air
Vent x1
Hose Clamps
(Not included)
4" Semi-Rigid
Metal Vent Tube
(Not Included)
Before installing the outside air kit to firebox, please make sure you have the following items:
If within one year from the date of original purchase, this item fails due to a defect in material or workmanship,
we will replace or repair at our option, free of charge. To order parts or to obtain warranty service,
call 1-877-447-4768, Monday - Friday, 8:30 a.m. - 4:30 p.m. CST. This warranty does not cover defects resulting from
improper or abnormal use, misuse, accident, or alteration. Failure to follow all instructions in the owner’s manual will also
void this warranty. The manufacturer will not be liable for incidental or consequential damages, or common erosion of
outdoor products. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights
which vary from state to state.
WARRANTY
This product can expose you to chemicals including Benzene which is
known to the State of California to cause cancer and reproductive harm.
For more information go to www.p65Warnings.ca.gov
If any part is missing or damaged, do not attempt to assemble the product. Contact our Technical Service Department at
1-877-477-4768 for replacement parts.
*The illustration provided is a simple outside are installation. Your installation may vary significantly but try to keep the
hose length to no more than 20 feet in length to provide sufficient air flow. Keep the inlet air vent level or below the
firebox entry if possible.
• Never terminate the “inlet air vent” in a garage.
• Make sure the “inlet air vent” is located in an area
which is free from snow build-up and dense bushes.
1. Place the insulation gasket between the open air kit
starting collar and fireplace wall.
2. Place the starting collar (4”) on the side of fireplace.
Fasten it in place with the four sheet metal screws provided.
NOTE: When the air starting collar is securely attached,
it will form a seal against the fireplace wall.
3. Attach outside duct to starting collar with duct clamp or screws.
4. Cut a 6-inch diameter opening for the open air kit in the
outside wall covering where the outside vent is to be located.
5. Select and cut a piece of duct long enough to attach
to the fireplace and stick out at least 3” beyond the
face of the wall to which the open air kit inlet air vent
will be attached. Cut duct with a standard pocket knife.
6. If the duct is the insulated type, push the insulation
back from one end of the duct approximately 2”.
7. Slip the exposed end of the duct over the starting
collar on the fireplace.
8. Using the sheet metal screws provided, secure the
duct end to the collar attached to the fireplace.
9. Nail or screw the combustion air assembly to the
surface of the wall.
WARNING!
Do not use a combustible duct. Always use UL Listed Class 0 or 1 duct material.
Insulation Gasket
PHOAK Starting Collar
(4) Sheet Metal Screws
PHOAK Inlet Air Vent
PHOAK Starting Collar
4” Semi-Rigid Metal
Vent Tube
Insulation Gasket
(4) #8 Wood Screws
(Not Included)
Inlet Air Vent
(4) #8 x 3/8
Sheet Metal Screws
Starting Collar
(2) 4” Clamps
(Not Included)