background image

Voice, Data, Video 

+

 Length

©2012 Platinum Tools Inc. All rights reserved. 5/12

Instruction Sheet: P/N T129

GENERAL SPECIFICATIONS

The Platinum Tools, VDV MapMaster2.0™ is a portable voice-data-video cable 

tester with length measurement. It tests and troubleshoots RJ11, RJ12, RJ45 and 

F-conector terminated cables and provides built-in tone generation for cable tracing.

BATTERY REPLACEMENT

1)

Remove single screw

 in the middle of the back

of the VDV MapMaster2.0™ with a #1 Phillips head

screwdriver. Remove the battery door.

2)

Remove the old battery

 and disconnect

battery cable.

3)

Replace with an ANSI 1604A

, 9 volt alkaline

battery (Energizer 522, Duracell Mn1604). Reattach

cable and insert into battery compartment.

4)

Replace battery door

 and screw.

DO NOT OVERTIGHTEN!

WARNINGS

To ensure safe operation and service of the tester, follow these instructions. 

Failure to observe these warnings can result in severe injury or death.

• The VDV MapMaster2.0™ is designed for use on unenergized cabling

systems. Connecting the VDV MapMaster2.0 to live AC power may

damage it and pose a safety hazard for the user.

• Poorly terminated RJ plugs have the potential to damage the jacks on the

VDV MapMaster2.0™. Visually inspect an RJ plug before inserting it into

the tester. The contacts should always be recessed into the plastic housing

of the plug. Plugging 6-position plugs into the 8-position jack on the

tester has the potential to damage the outermost contacts of the jack

unless the plug is specifically designed for that purpose.

1

Coax Type

Belden P/N   Shield  Maximum Length

RG-58A/U

8259 

14.9

Ω

 / 1,000 ft 

6,710ft (2,045m)

9311 

25.8

Ω

 / 1,000ft 

3,876ft (1,182m)

7806A 

11.8

Ω

 / 1,000ft 

8,475ft (2,583m)

RG-59/U 

9310 

24.1

Ω

 / 1,000ft 

4,150ft (1,265m)

9259 

23.5

Ω

 / 1,000ft 

4,255ft (1,297m)

8241A 

49.7

Ω

 / 1,000ft 

2,010ft (613m)

9275 

78.5

Ω

 / 1,000 

1,275ft (389m)

9659 

17.6

Ω

 / 1,000ft 

5,682ft (1,732m)

RG-6/U 

1694A 

7.2

Ω

 / 1,000ft 

13,889ft (4,234m)

1152A 

29.8

Ω

 / 1,000ft 

3,360ft (1,025m)

Mini Coax 

9221 

111

Ω

 / 1,000ft 

900ft (275m)

RG-11/U 

1523A 

15.1

Ω

 / 1,000ft 

6,623ft (2,019m)

Dimensions:

6.4˝ x 2.8˝ x 1.4˝ (16.3 x 7.1 x 3.6 cm)

Weight:

 9.0 oz. (256 grams)

with battery and remote

Operating Temperature:

0˚C/32˚F to 50˚C/122˚F

Storage Temperature:

-20˚/-4˚F to 60˚C/140˚F

Humidity:

 10% to 90%, 

non-condensing

Maximum Voltage

 between

any two connector pins without

damage:

RJ Jack: 66V DC or 55V AC

F-Connector: 50V DC or AC

Battery Life:

 9V alkaline

battery typical

Standby: 4 years

Active: 425 hours

Cable Types:

 Shielded or

Unshielded; Cat7, Cat6x, Cat5e, 

Cat5, Cat4, Cat3, Coax

Maximum RJ Cable Length:

0 to 1,000 feet (305 meters)

Minimum Cable Length for Split

Pair Detection:

 1.5 feet (0.5 meters)

Low Battery:

 Icon flashes when

battery voltage falls below 6V

Measurement Technology:

Capacitance testing

Length Accuracy Without

Length Constant Accuracy:

± 3% plus ± 1 foot

Cable Length Measurement:

1 to 2,000 ft CAT5E cable with

15 pF/ft length constant

Default Length Constant:

Restored with power on reset

• Voice: 17.4 pF/ft

• Video: 16.5 pF/ft

• Data: 15 pF/ft

       Complies with Conformité 

       Européenne directives.

Maximum Coax Cable Length:

99 Washington Street