background image

  
 

ToneMaster

TM

 Tone Generator User Instructions  

Part Numbers: TG210/TG220

 

 

Warning! Do not attach to live AC circuits. This could cause an extreme shock hazard and damage 

the tone generator. To prevent damage to your tone generator always set the tone generator to 

STATUS mode before connecting to any circuit. 
 

FEATURES  

• 

Four tone amplitude configurations: Half, Full, High-Powered Half and High-Powered Full 

• 

Half amplitude is unbalanced for stronger tone on twisted pairs  

• 

Three distinctly different tones selected from front panel  

• 

Constant Amplitude tone over life of battery for 100% tone strength all the time 

• 

Auto-off — tone turns off after 15 minutes; prevents having dead battery if left on  

• 

Tone may be added in any mode — allows phone sets without monitor feature to pick up tone  

• 

No power draw in continuity mode with leads open— no dead battery if left in continuity  

• 

Polarity indicator for phone lines 

• 

RJ jack allows use of modular cable without adapters  

• 

Use as Talk Battery to test dry phone (unpowered) lines 

 

Note: 

The RJ jumper cable that has been provided with the tone generator uses a uniquely-colored 

no-fault modular connector that can be plugged into an RJ12 jack or RJ45 jack. 

 

 

INSTRUCTIONS FOR USE 
 

To send a tone for tracing

 

1.  Move the slide switch on left side of tone generator to the TONE position for normal operation.  

2.  Connect the test lead(s) to a wire or both wires in a wired pair. Otherwise attach one lead to the wire 

of a cable or attach one lead to one wire in paired wires being traced. A modular phone cable can be 

used to connect the tone generator directly to a wall jack.  

3.  Press the TONE button briefly to turn on the tone. Press the TONE button to cycle through the different tone configurations.  

4.  Hold a tone tracer probe near the jack to hear each tone type as it is selected. 
 
 
 
 
 
 
 
 
 
 
 
 
 

5.  To turn off the tone, press and hold the TONE button until no LED’s are lit. After 15 minutes the tone generator will turn off             

automatically.  

6.  To change the cadence, press the TONE CADENCE button to cycle through constant, warbling, high-frequency constant, and war-

bling high-frequency tones. 

 

Application Hints: 

• 

For long runs and when used with twisted pair cables, turning on the HIGH-POWERED mode increases the tone amplitude by over 
700% but will also use more battery power.  

• 

The normal amplitude mode uses the minimum battery power. Use the normal power amplitude setting if there is too much bleeding 
of the tone into adjacent wires.  

• 

For twisted pairs, connect the clips from the tone generator to the wires of separate pairs. Connecting to wires in the same pair will 
result in a softer tone and tends to contain the tone within the cable. With softer tones, the tracer must nearly touch the end of the 

cable to detect the tone. This is the case if the cable is terminated with a connector or a jack. 

• 

To maximize the tone while tracing along a cable run, connect one lead of the tone generator to the wire or cable and the other end to 
an earth ground (such as the case of an electrical box, electrical conduit, metallic water pipe or ground rod). If no ground is available, 

do not connect the other lead to anything; let it dangle as near to the earth as possible.  

• 

To block tone over-bleeding on coax cables, connect one lead to the center pin and the other lead to the ungrounded shield of the 
cable.  

 

 
 
 
 

Test leads 

RJ12 Jack 

Test Mode  

Cadence Button 

Telephone Test Indicators 

Tone Power Mode 

Tone Lead Selection 

Tone Button 

Battery Level 

10 

Test Mode Switch 

Normal Power

 

 

Normal Power

 

 

High Powered

 

 

High Powered

 

 

 

Half

 

Full

 

Half

 

Full

 

Red Lead (1)

 

Black Lead (2)

 

Full

 

Full

 

Full

 

Full

 

Reviews: