I - GENERAL INSTRUCTIONS

Plastimo offers a complete range of inflatable lifejackets to suit all types of uses.
Those models are equipped with a manual, automatic or hydrostatic firing head. Each lifejacket can also be manually inflated if 
necessary.
These lifejackets have been designed for a people weighing over 40 kg and with a waist measurement between 60 and 130 cm 
or between 130 and 170cm depending on the model.
Lifejackets only reduce the risk of drowning; they are not a life-saving guarantee.
Inflatable lifejackets are available with or without safety harness.
CAUTION :  The deck safety harness and its tether are intended to prevent the wearer from falling overboard, they do not 
provide protection against falls from a height. It is dangerous to wear this harness not tightened correctly. Also, harness must be 
adjusted to be efficient.The deck harness and the tether may transmit very large forces to the anchorage point. Only fasten to 
anchorage points or strong jacklines.
 Anchorage points shall be able to withstand forces of more than 2 tons.
The harness should be used in conjunction with an EN ISO 12401 approved tether.

II - INSTRUCTIONS FOR USE

To be used for offshore navigation, this enables to wear stormy weather clothing.
This lifejacket only functions when fully inflated. When inflated, it will turn most users face up, even unconscious. 

Do not sit down on the lifejacket. Do not use as a cushion.
The performances of your lifejackets can be altered when using some kind of waterproof clothing or in other circumstances. Do 
not wear an inflatable lifejacket under any clothing or safety harness. This is not a lifejacket until fully inflated.

1- Inspection before use

Perform a visual inspection prior to using:Check the lifejacket is not damaged. Make sure the CO2 cylinder is full and firmly 
screwed and ensure the firing handle is visible outside the lifejacket cover.
Check the colour of the firing indicator.

1a – Manual inflation lifejacket

Green indicator: inflation mechanism ready to operate.
Red indicator : inflation mechanism out of service. The inflation system must be rearmed (refer to § Rearming instructions).

1b - Automatic inflation lifejacket – grey model

Green indicator: inflation mechanism ready to operate.
At least one red indicator or both : inflation mechanism out of order. The inflation system must be rearmed (refer to § Rearming 
instructions).

1c- Automatic inflation lifejacket – yellow model

Green indicator: inflation mechanism ready to operate.
At least one green indicator off or both : inflation mechanism out of order. The inflation system must be rearmed (refer to § 
Rearming instructions).

1d – Hydrostatic inflation lifejacket

Green indicator: inflation mechanism ready to operate.
Red indicator : inflation mechanism out of service. The inflation system must be rearmed (refer to § Rearming instructions).

M

 Check also the expiry date on the water-dissolving cartridge or the hydrostatic firing system. If the expiry date is exceeded, 

the inflation system is out of order. The water-dissolving cartridge or the hydrostatic firing system must be replaced (refer to § 
Rearming instructions).

2 - Donning instructions

Put on the lifejacket like a jacket. 
Fasten the buckle in front.
Tighten and adjust the belt.

3 - Inflation

Inflation can be triggered in 3 different ways: 
3a - Manual inflation: pull the activating handle sharply downward.
3b - Automatic inflation (Available only for lifejackets with automatic or hydrostatic firing head): Inflation starts automatically 
after the lifejacket comes in contact with water.
3c - Oral inflation: open the top cap and blow in the oral inflation tube. Oral inflation can be used as a back-up or as an 
emergency method of inflation.
Warning: Never activate the firing system if the lifejacket is already partially or fully inflated.

4 - Re-arming instructions

Before re-arming your lifejacket, clearly identify which firing head is fitted on.

4a - Manual lifejacket

After manual inflation, fold back the firing lever into normal position until the “clic”. Unscrew the used CO2 gas bottle.  Firmly 
screw on the new CO2 gas bottle.

4b- Automatic inflation lifejacket – grey model

After manual inflation, fold back the firing lever into normal position until the “clic”. Unscrew the used CO2 gas bottle. Firmly 
screw on the new CO2 gas bottle.

Never wear a lifejacket without adjusting the fit : we recommend you to try out your lifejacket in order to practice adjusting it and 
obtain a proper fit. 

GB

GB

-4-

9 mars 2011
60535.cdr

IMPRESSION PANTONE 072

SUPPORT : OFFSET 80 GRS

Summary of Contents for PILOT 150N

Page 1: ...OMATISCHE REDDINGVESTEN GEBRUIKERSHANDLEIDING NL GIUBBOTTI DI SALVATAGGIO GONFIABILI MANUALE D USO I CHALECOS HINCHABLES GUIADE UTILIZACION E ILMAT YTTEISEN PELASTUSLIIVIN K YTT J N OHJEKIRJA FIN FELF...

Page 2: ......

Page 3: ...3...

Page 4: ...Rearming instructions 1b Automatic inflation lifejacket grey model Green indicator inflation mechanism ready to operate At least one red indicator or both inflation mechanism out of order The inflati...

Page 5: ...cket cover III MAINTENANCE AND CARE INSTRUCTIONS After each use dry your lifejacket thoroughly and keep it clean and free from oil and sand Store it away from direct sunlight Your lifejacket shall be...

Page 6: ...chement manuel T moin vert Syst me de gonflage en tat de fonctionner T moin rouge Syst me de gonflage hors service Le syst me de gonflage doit tre r arm voir Recharge du gilet 1b Gilet d clenchement a...

Page 7: ...ectement et v rifier que la poign e de d clenchement est visible l ext rieur du gilet III ENTRETIEN Veiller toujours bien s cher le gilet apr s chaque utilisation et le garder propre sans graisse ni s...

Page 8: ...Se kapittel 4 for instruksjon for tilbakestilling 1b Automatisk utl sningsmekanisme gr modell Gr nn indikator utl sningsmekanismen er OK En eller to r de indikatorer utl sningsmekanismen fungerer ikke...

Page 9: ...for luft ved trykke ned ventilen p toppen av slangen Kontroller at flytevesten er t rr og tom for luft Legg flytevesten p en plan overflate Brett sidene av vesten som vist p side 28 og 29 Plasser bor...

Page 10: ...hanisme 1a Handmatige ontsteking Groene indicators ontstekingsmechanisme gereed voor gebruik Rode indicator ontstekingsmechanisme niet gereed voor gebruik Het ontstekingsmechanisme moet worden herlade...

Page 11: ...opblaasbuisje Zorg ervoor dat uw reddingvest droog en volledig leeggelopen is Leg uw reddingvest op een vlakke ondergrond Vouw de zijkanten van het reddingvest zoals getoond op de tekeningen op bladz...

Page 12: ...hinchado manual es visible fuera de la cubierta del chaleco Verificar el color del indicador del disparo hidrost tico 1a Hinchado manual Indicador verde sistema de hinchado listo para su funcionamien...

Page 13: ...ndo la v lvula del tubo bucal Asegurarse de que el chaleco est completamente seco y deshinchado Extender el chaleco sobre una superficie plana Plegar los extremos como se describe en los esquemas de l...

Page 14: ...kanism Gr n indikering utl sningsmekanismen r OK R d indikering utl sningsmekanismen r ur funktion Se kapitel om 4 med omladdningsinstruktioner 1b Automatisk utl sningsmekanism gr modell Gr n indikeri...

Page 15: ...uppbl sningsr ret F rs kra er om att flytv sten r torr och tom p luft Placera flytv sten p ett plant underlag Vik sidorna av flytv sten som visas p sid 28 29 St ng kardborrebanden korrekt och kontroll...

Page 16: ...rmato vedere il capitolo istruzioni di ricarica 1b Giubbotto ad attivazione automatica modello grigio Indicatore verde dispositivo di gonfiaggio pronto per l utilizzo Uno od entrambi gli indicatori ro...

Page 17: ...o sia visibile dal rivestimento esterno del giubbotto III CURA E MANUTENZIONE Dopo ogni utilizzo asciugare con attenzione il giubbotto e tenerlo al riparo da sostanze oleose e sabbia Conservare lontan...

Page 18: ...I H Plastimo 40 60 130 130 170 Jacklines 2 ISO 12401 II t f sete sa s s t e a e as e te e t f e a t s s p e a p e te a t p sa ete s s t a a p e te se d ap t e 1 CO2 1 1 1 1 2 3 3 3 3 3 4 4 CO2 CO2 4...

Page 19: ...CO2 4 1 CO2 CO2 CO2 CO2 CO2 5 28 29 velcro III 12 Plastimo CO2 Plastimo 2 IV Plastimo 34 V 2 30 33 VI CE CE 0501 CRITT Sport Loisir ZA du Sanital 86100 Ch tellerault FRANCE CE 0082 APAVE SUDEUROPE SAS...

Page 20: ...n t ynn ja tukevasti kiinni varmista my s ett laukaisunaru on n kyviss liivin ulkopuolella Tarkista laukaisin osoittimen v ri 1a Manuaalinen ilmat ytteinen pelastusliivi Vihre osoitin t ytt mekanismi...

Page 21: ...appaleen putken p ss Varmista ett liivi on varmasti kuiva ja tyhj Aseta liivi tasaiselle pinnalle Taita liivin sivut kuten on n ytetty kuvassa sivulla 28 29 Kiinnit tarrat oikein ja tarkista ett lauka...

Page 22: ...ny bor t s n k v l tal lhat Ellen rizze az els t s meg rt nt t mutat kijelz sz n t 1a K zi felf j s ment mell ny Z ld kijelz A felf j szerkezet m k d sre k sz Piros kijelz A felf j szerkezet nem m k d...

Page 23: ...n l that a 28 29 oldalon Megfelel en illessze ssze a t p z rakat s ellen rizze hogy a m k dtet foganty a mell nyen k v l legyen tal lhat III ZEMBEN TART SI S KEZEL SI UTAS T SOK Minden haszn lat ut n...

Page 24: ...c vesta este deteriorat dac cartu ul de CO2 este plin i str ns nfiletat i asigura i v c m nerul de declan are este vizibil la exteriorul vestei Verifica i culoarea indicatorului de declan are 1a Vest...

Page 25: ...pozi ie orizontal mp turi i marginile vestei conform schemei de la pagina 28 29 Pozi iona i corect benzile velcro i verifica i dac m nerul de declan are este vizibil la exteriorul vestei III NTRE INER...

Page 26: ...gr model Gr n indikation udl ser er OK En eller to r de indikatorer udl sningsmekanisme er ude af drift Se kapitel 4 i genil gning 1c automatiske udl sningsmekanisme gul model Gr n indikation udl ser...

Page 27: ...ist p side 28 29 Luk velcro korrekt og kontrollere aktiveringen h ndtaget er klart synlig uden for yderstof III VEDLIGEHOLDELSE Efter hver brug skal du s rge for at t rre vesten Hold den ren og fri fo...

Page 28: ...28 1 2 3 4 5 6 JE RK TO IN FL AT E JE RK TO IN FL AT E 7 JE RK TO IN FL AT E JE RK TO IN FL AT E 8...

Page 29: ...9 10 11 12 13 14 15 16 JE RK TO IN FL AT E JE RK TO IN FL AT E INSIDE JE RK TO IN FL AT E JE RK TO IN FL AT E JE RK TO IN FL AT E I N S I D E JE RK TO IN FL AT E JE RK TO IN FL AT E JE RK TO IN FL AT...

Page 30: ...DK Poign e de d clenchement Asa de hinchado manual Manopola di attivazione Aktiverings handtag Ontstekingshendel Utl sningsh ndtak Activating handle Aktivering H ndtag M k dtet foganty Laukaisunaru T...

Page 31: ...spinne Ontstekingshendel Automatische smeltcapsule of cilinder CO2 gaspatroon Borgclip Activating handle Automatic water dissolving cartridge CO2 gas bottle Locking clip Automatisk vandopl selig kapse...

Page 32: ...2 CO2 bombola gas CO2 gas flaska CO2 gaspatroon CO2 gas bottle Gasflaske med CO2 CO2 CO2 palack Poign e de d clenchement Asa de hinchado manual Manopola di attivazione Aktiverings handtag Ontstekingsh...

Page 33: ...bottle Hydrostatisk patron CO2 Els t fej M k dtet foganty Hidrosztatikus rz kel sapka CO2 palack Firing indicator HYDROSTATIC Asa de hinchado manual Indicador de estado de cabeza de percusi n Laukaisu...

Page 34: ...33 gr 33 gr 33 gr HYDROSTATIC MANUAL JER K TO INFL ATE AUTOMATIC 40199 kit ref 58460 58461 34 33 gr 40255 40200 58505...

Page 35: ......

Page 36: ...60535...