Copyright Planika Sp. z o.o.
www.planikafires.com
IG0033#08
2020-03-20
22
•
This can take few seconds to ignite to pilot flame especially when you have replaced and installed a new LPG gas
cylinder.
•
If the pilot light does not ignite after 3 ignition attempts close the gas tap and warn the fitter.
•
Once the pilot light is burning, the main burner must ignite within 10 seconds automatically. If this does not
happen, immediately close the gas tap and warn the fitter.
•
If the main burner ignites with a pop immediately close the gas tap and warn the fitter.
WARNING!!!
•
Under conditions of increased humidity (rain, breeze, fog, dew, etc.),
there may be some temporary problems with switching on the fireplace.
This is a normal phenomenon associated with the dampening of the
ignition element.
•
Before switching on the fireplace, wait until the ignition element has dried
completely.
•
You can speed up this process by blowing the pilot flame with compressed
air to remove the accumulated moisture. The properly fired pilot flame
consist of 3 smaller parts.
4.4.5.
Gradually decrease flame height
After ignition, the burner automatically sets the
flames to the maximum height.
Press
button to lower the flames and to turn
off the burner.
Pressing briefly the
button gradually lowers
the flames to the low position.