1-Port 10/100/1000T 802.3at PoE +
Ethernet to VDSL2 Converter
VC-231GP
User’s Manual
Page 1: ...1 Port 10 100 1000T 802 3at PoE Ethernet to VDSL2 Converter VC 231GP User s Manual...
Page 2: ...s not represent a commitment on the part of PLANET PLANET assumes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep curren...
Page 3: ...t Without removing power cable the device will still consume power from the power source In view of Saving the Energy and reducing the unnecessary power consumption it is strongly suggested to remove...
Page 4: ...r Panel and Mode DIP Switch 10 3 3 Power Information 13 4 Connecting And Using The VDSL2 Bridge 14 4 1 Point to Point Application LAN to LAN Connection 15 4 2 Point to Multipoint Application Connect t...
Page 5: ...ld contain the following items VC 231GP x1 User s Manual x 1 RJ11 Telephone Wire x 1 Splitter x 1 AC DC Power Adapter Input 54V DC 0 74A max x 1 If any of these are missing or damaged please contact y...
Page 6: ...to detects IEEE 802 3at af equipment and protects devices from being damaged by incorrect installation Remote power feeding up to 100m IEEE 802 3at af splitter devices compatible VDSL2 Features Cost e...
Page 7: ...tion time Simply by Plug and Play Supports extensive LED indicators for network diagnosis Layer 2 Features Supports auto negotiation and 10 100Mbps half full duplex and 1000Mbps full duplex mode on RJ...
Page 8: ...igure 3 1 1 VC 231GP Front Panel f f 10 100 1000BASE T RJ45 connector for Ethernet and 802 3at af PoE injector f f RJ11 connector for VDSL2 connect to IP DSLAM or another VDSL2 equipment f f LEDs for...
Page 9: ...mode 10 100 1000BASE T 802 3at PoE Port LED Color Function 1000 Green Lit Indicates that the port is operating at 1000Mbps Blink Indicates that the VC 231GP actively sending or receiving data over th...
Page 10: ...GP Rear Panel f f DIP switch f f DC jack DC input for power adapter DC Power Jack The VC 231GP requires 54V DC 0 74A power input which conforms to the bundled AC DC adapter Should you have the issue o...
Page 11: ...bandwidth and distance extensibility tested for AWG 24 0 5mm twisted pair without noise and cross talk DIP 1 DIP 2 DIP 3 DIP 4 Mode Transmission Band Profile SNR Margin OFF CO G INP Asymmetric 12dB ON...
Page 12: ...h than the other side This mode provides the highest bandwidth in short range Symmetric With G 997 band plan supported symmetric mode can provide almost the same rate of downstream and upstream DIP 4...
Page 13: ...5mm wide that require 54VDC power input They conform to the bundled AC DC adapter Should you have the issue of power connection please contact your local sales representative 2 1mm Width of DC Recept...
Page 14: ...ephone lines The VC 231GP provides only one RJ11 connector for VDSL2 port to build VDSL2 connection For voice device connec tion there is an additional splitter from the package of the VC 231GP which...
Page 15: ...ridge must be Master CO mode and the other one is Slave CPE mode VC 231G CO LAN to LAN Connection Up to 1 4km VDSL2 Telephone Wire Splitter Splitter Phone Main Office PBX Telco Co wire closet Main Off...
Page 16: ...n the VC 231G CO and VC 231GP CPE at both sides by connecting its power source 4 Power LED will illuminate 5 Connect VDSL line from another VDSL device to RJ11 VDSL port of the VC 231G VC 231GP 6 VDSL...
Page 17: ...n the other hand it needs to install one or many CPE Slaves the VC 231GP on the individual client side and connect to the multi port Master through the telephone lines Multi LAN Connection Phone Phone...
Page 18: ...11 Phone port of the VC 231GP 8 Connect the VC 231GP Ethernet LAN port to other network device via regular Cat 5 UTP cable When deciding where to put the converter and or prolong the operational life...
Page 19: ...itter for POTS connection Dimensions W x D x H 97 x 70 x 26 mm Weight 206g Power Requirement DC 54V 0 74A external power LED Indicators System Power Green TP port 100BASE TX LNK ACT Green 1000BASE T L...
Page 20: ...nt 1 2 3 6 PoE Power Budget 30 watts Switch Specifications Switch Processing Scheme Store and Forward Address Table 2K entries Flow Control Back pressure for half duplex IEEE 802 3x pause frame for fu...
Page 21: ...t Ethernet IEEE 802 3ab Gigabit Ethernet IEEE 802 3x Full duplex Flow Control IEEE 802 1p Class Of Service IEEE 802 3af Power over Ethernet IEEE 802 3at Power over Ethernet Plus ITU T G 993 1 VDSL ITU...
Page 22: ...42 36 1000m 49 10 44 10 26 16 23 12 1200m 39 8 32 6 26 12 23 10 1400m 25 6 22 3 29 12 17 11 Distance meter G INP Downstream Upstream Asymmetric Symmetric 8dB 12dB 8dB 12dB 200m 192 93 177 85 150 150...
Page 23: ...her work SYMPTOM TP LED does not light after cable is connected to the port CHECKPOINT 1 Verify you are using the Cat 5 or better cable with RJ45 connector to connect to the port 2 If your device like...
Page 24: ...ations the SNR will probably cause a reduction in data speed because of frequent errors that require the source transmitting computer or terminal to resend some packets of data SNR measures the qualit...
Page 25: ...information please contact PLANET converter support team PLANET online FAQs http www planet com tw en support faq php type 1 Converter support team mail address support planet com tw Copyright PLANET...
Page 26: ...unt Installation Step 1 Please find the wall that can mount the VC 231GP Step 2 Screw two screws on the wall Step 3 Hang the VC 231GP on the screws from the wall Step 4 Refer to chapter 3 3 Power Info...
Page 27: ...27 RJ45 UTP Cable RJ11 Ethernet over VDSL 2 Converter 5V DC CO CPE G INP Interleave 8dB 12dB OFF ON Mode Tran Sym Asym Band SNR 1 2 3 4 ON...
Page 28: ...equirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on 2014 30 EU For the evaluation regarding the EM...