PLANET NAS-7400 User Manual
105
i.
In the Tree, click on the + beside the Management icon.
ii.
Click on the APC UPS icon.
iii.
The Information tab displays the status of the UPS.
iv.
If there is no UPS connected or recognized, the Status field reports
“NO UPS.”
6.7.8 Setting up a UPS
To set up a UPS:
i.
Attach the APC UPS to one of the NAS-7400’s USB ports.
ii.
In the Tree, click on the + beside the Management icon.
iii.
Click on the APC UPS icon.
iv.
Click on the Setup tab.
The Setup tab enables you to tell the NAS-7400 how and when to
shutdown after a power failure.
Click the option button beside the shutdown option you want:
•
Disable - The NAS-7400 will continue to run until the UPS battery
is depleted
•
Shutdown when the UPS reaches a set percentage of reserve
power
•
Shutdown when the UPS reaches a set number of minutes of
remaining runtime
•
Shutdown after running on the UPS batteries for a set number of
minutes
v.
If you selected battery percentage, type a percentage amount in
the % field.
vi.
If you selected running time, type the number of minutes into the
Mins. field.
vii.
Click the OK button.