User’s Manual of MGSD-10080F
102
4.3.4.2 SNMPv3 Users
Configure SNMPv3 users table on this page. The entry index keys are Engine ID and User Name. The SNMPv3 Users screen in
Figure 4-3-4
appears.
Figure 4-3-4:
SNMPv3 Users Configuration Page Screenshot
The page includes the following fields:
Object
Description
•
Delete
Check to delete the entry. It will be deleted during the next save.
•
Engine ID
An octet string identifying the engine ID that this entry should belong to. The
string must contain an even number (in hexadecimal format) with number of
digits between 10 and 64, but all-zeros and all-'F's are not allowed. The SNMPv3
architecture uses the User-based Security Model (USM) for message security
and the View-based Access Control Model (VACM) for access control. For the
USM entry, the usmUserEngineID and usmUserName are the entry's keys. In a
simple agent, usmUserEngineID is always that agent's own snmpEngineID
value. The value can also take the value of the snmpEngineID of a remote SNMP
engine with which this user can communicate. In other words, if user engine ID
equal system engine ID then it is local user; otherwise it's remote user.
•
User Name
A string identifying the user name that this entry should belong to. The allowed
string length is 1 to 32, and the allowed content is the ASCII characters from 33
to 126.
•
Security Level
Indicates the security model that this entry should belong to. Possible security
models are:
NoAuth, NoPriv
: None authentication and none privacy.
Auth, NoPriv
: Authentication and none privacy.
Auth, Priv
: Authentication and privacy.
The value of security level cannot be modified if entry already exist. That means
must first ensure that the value is set correctly.
•
Authentication
Protocol
Indicates the authentication protocol that this entry should belong to. Possible
authentication protocol are:
None
: None authentication protocol.
MD5
: An optional flag to indicate that this user using MD5
Summary of Contents for MGSD-10080F
Page 1: ...User s Manual of MGSD 10080F 1 ...
Page 43: ...User s Manual of MGSD 10080F 43 Figure 2 8 Wires DO0 and DO1 to Open Detector ...
Page 276: ...User s Manual of MGSD 10080F 276 Figure 4 11 15 Windows 2003 AD Server Setting Path ...
Page 358: ...User s Manual of MGSD 10080F 358 ...
Page 488: ...User s Manual of MGSD 10080F 488 Example Disable SMAC mode MGSD 10080F Aggr mode smac disable ...
Page 554: ...User s Manual of MGSD 10080F 554 Activate the alternate firmware image Syntax Firmware Swap ...
Page 603: ...User s Manual of MGSD 10080F 603 SMTP Test ...
Page 616: ...User s Manual of MGSD 10080F 616 Syntax Show STP ...