User’s Manual of IGS-20040MT
2.1.4 Switch Upper Panel
The Upper Panel of the
Industrial Managed Switch
indicates a DC inlet power socket and consist one terminal block
connector within 6-contacts. It accepts input power from 12 to 48V DC and 24V AC.
1.
Insert positive / negative DC power wires into contacts 1 and 2 for DC Power 1, or 5 and 6 for DC Power 2.
Figure 2-3: IGS-20040MT
Upper Panel
2.
Tighten the wire-clamp screws for preventing the wires from loosening.
1 2
3 4 5
6
DC
1 DC
2
+ - +
-
Figure 2-4
6-Pin Terminal Block Power Wiring Input
1. The wire gauge for the terminal block should be in the range of 12 ~ 24 AWG.
2. When performing any of the procedures like inserting the wires or tighten the wire-clamp screws,
make sure the power is OFF to prevent from getting an electric shock.
26