User’s Manual
170
•
Port Error Recovery
Control whether a port in the error-disabled state automatically will be enabled
after a certain time. If recovery is not enabled, ports have to be disabled and
re-enabled for normal STP operation. The condition is also cleared by a system
reboot.
•
Port Error Recovery
Timeout
The time that has to pass before a port in the
error-disabled
state can be
enabled. Valid values are between 30 and 86400 seconds (24 hours).
The Industrial Managed Switch implements the Rapid Spanning Protocol as the default spanning
tree protocol. When selecting
“Compatibles”
mode, the system uses the RSTP (802.1w) to be
compatible and to co-work with another STP (802.1D)’s BPDU control packet.
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
4.7.3 Bridge Status
This page provides a status overview for all STP bridge instances. The displayed table contains a row for each STP bridge
instance, where the column displays the following information. The Bridge Status screen in
Figure 4-7-5
appears.
Figure 4-7-5:
STP Bridge Status page Screenshot
The page includes the following fields:
Object
Description
•
MSTI
The Bridge Instance. This is also a link to the STP Detailed Bridge Status.
•
Bridge ID
The Bridge ID of this Bridge instance.
•
Root ID
The Bridge ID of the currently elected root bridge.
•
Root Port
The switch port currently assigned the
root
port role.
•
Root Cost
Root Path Cost. For the Root Bridge this is zero. For all other Bridges, it is the
sum of the Port Path Costs on the least cost path to the Root Bridge.
Summary of Contents for IGS-10020
Page 1: ...User s Manual...
Page 31: ...User s Manual 31 IGS 10020PT IGS 10020PT Dimensions W x D x H 72 x 107 x 152mm...
Page 32: ...User s Manual 32 IGS 10020HPT IGS 10020HPT Dimensions W x D x H 72 x 107 x 152mm...
Page 33: ...User s Manual 33 IGS 10080MFT IGS 10080MFT Dimensions W x D x H 72 x 107x 152mm...
Page 34: ...User s Manual 34 IGS 12040MT IGS 12040MT Dimensions W x D x H 72 x 107 x 152mm...
Page 35: ...User s Manual 35 IGS 20040MT IGS 20040MT Dimensions W x D x H 72 x 107 x 152mm...
Page 36: ...User s Manual 36 IGS 20160HPT IGS 20160HPT Dimensions W x D x H 84 x 107 x 152mm...
Page 46: ...User s Manual 46 Figure 2 16 IGS 10080MFT Upper Panel Figure 2 17 IGS 12040MT Upper Panel...
Page 47: ...User s Manual 47 Figure 2 18 IGS 20040MT Upper Panel Figure 2 19 IGS 20160HPT Upper Panel...