background image

 

 

 

 

 

 

User's Manual 

 

 

 

 

FST-801 

FST-802 

FST-802S15/802S35/802S50 

FST-806A20/806B20 

 

10/100Base-TX to 100Base-FX 

Smart Media Converter 

 

 
 
 
 
 
 
 

 

 

 

 

 

- 1 - 

Summary of Contents for FST-801

Page 1: ...User s Manual FST 801 FST 802 FST 802S15 802S35 802S50 FST 806A20 806B20 10 100Base TX to 100Base FX Smart Media Converter 1...

Page 2: ...environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful interference to radio communi...

Page 3: ...INTO MC 1600MR R48 CHASSIS INSTALLATION 8 2 3 REAL ETHERNET ENVIRONMENT APPLICATION 9 3 MANAGE THE MEDIA CONVERTER 10 3 1 DIP SWITCH CONFIGURATION 10 3 2 MANAGED MEDIA CONVERTER MODULE THROUGH MC 160...

Page 4: ...nk issue and provide efficient solution to monitor the entire network The FST 80x series Smart Media Converter can allow two type segments connect easily with efficiently and cost effective these Smar...

Page 5: ...er cable up to 2km 9 125 m single mode cable provide long distance for 15 20 35 50km Maximum Cable distance MM 2km MM 2km SM 15km SM 35km SM 50km SM 20km Single wire SM 20km Single wire LED indicator...

Page 6: ...rating at 10Mbps Lights On Connection at Full Duplex mode Lights Off Connection at Half Duplex mode TP FDX COL Green Lights Blinking The port is experiencing collisions Lights On The link through that...

Page 7: ...ice station in a network to which the FST 80X will be attached Ensure that there is no activity in the network Attach fiber cable from the FST 80X to the fiber network TX RX must be paired at both end...

Page 8: ...an empty expansion slot on the front of the chassis The FST 80x Media Converter board can be installed in any expansion slot Step 3 Slide the FST 80x Media Converter board into the expansion slot alig...

Page 9: ...ent network application it is very flexible for FST 80x work as a standalone devices or install into the central Web Smart Media converter chassis for centralize management Once install into Web Smart...

Page 10: ...Half Full duplex mode LLR Disable Enable LLCF Disable Enable Please refer to the table below for more detail decription DIP Switch Mode Description On Fiber operates at Half Duplex mode DIP Switch 1 O...

Page 11: ...ch as fiber HDX FDX UTP Auto negotiation Manual speed 10 100Mbps duplex mode Half Full duplex mode LLR Disable Enable LLCF Disable Enable Item Description Device To enable or disable per FST 80x Conve...

Page 12: ...ts do not transmit a link signal until they receive a link signal from the opposite port The diagram below shows a typical network configuration with a good link status using FST 80X for remote connec...

Page 13: ...ation LED lit established link LED unlit no link LLCF is ON LLCF is ON Fiber Cable If one of the optical conductors is bad as shown in the diagram box below the converter with LLR enabled will return...

Page 14: ...correct 2 Please check the 100Base FX interface from both devices run at the same full or half duplex mode 10 100Base TX port link LED is lit but the traffic is irregular Solution 1 Check that the at...

Page 15: ...t used 6 Rx receive Tx transmit 7 8 Not used A 2 RJ 45 cable pin assignment The standard RJ 45 receptacle connector There are 8 wires on a standard UTP STP cable and each wire is color coded The follo...

Page 16: ...Half Node to Node Node to Switch 412 meters MM Full Node to Node Node to Switch 2 kilometers Single Mode Converters FST 80xynn x 2 6 y S A B nn km SM Full Node to Node Node to Switch Depends on model...

Page 17: ...e evaluation regarding the EMC the following standards were applied Emission EN 55022 1994 A1 1995 A2 1997 Class A Harmonic EN 61000 3 2 2000 Flicker EN 61000 3 3 1995 A1 2001 Immunity EN 55024 1998 E...

Page 18: ...luation regarding the EMC the following standards were applied Emission EN 55022 1994 A1 1995 A2 1997 Class A Harmonic EN 61000 3 2 2000 Flicker EN 61000 3 3 1995 A1 2001 Immunity EN 55024 1998 ESD IE...

Page 19: ...n regarding the EMC the following standards were applied Emission EN 55022 1994 A1 1995 A2 1997 Class A Harmonic EN 61000 3 2 2000 Flicker EN 61000 3 3 1995 A1 2001 Immunity EN 55024 1998 ESD IEC 6100...

Reviews: