background image

 

 

 

 

 

 

 

 

 

5-Port 10/100Mbps Fast Ethernet Switch   
with 802.3af splitter built-in 
 

FSD-504PE 

 

User’s Manual 

Summary of Contents for FSD-504PE

Page 1: ...5 Port 10 100Mbps Fast Ethernet Switch with 802 3af splitter built in FSD 504PE User s Manual ...

Page 2: ...ight to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incomplete we would appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC...

Page 3: ...GUIDE 4 Chapter 1 INTRODUCTION 5 Chapter 2 UNPACKING AND SETUP 9 Chapter 3 IDENTIFYING EXTERNAL COMPONENTS 10 Chapter 4 CONNECTING THE SWITCH 12 Chapter 5 TECHNICAL SPECIFICATIONS 15 APPENDIX A RJ 45 PIN SPECIFICATION 16 APPENDIX B SWITCH OPERATION 18 ...

Page 4: ... the information you need to install and configure the FSD 504PE Overview of this User s Manual Chapter 1 Introduction Describes the Switch and its features Chapter 2 Unpacking and Setup Helps you get started with the basic installation of the Switch Chapter 3 Identifying External Components Describes the front panel rear panel and LED indicators of the Switch Chapter 4 Connecting the Switch Tells...

Page 5: ...vironments it provides a straightforward upgrade and takes advantage of the existing investment in hardware software and personnel training Switching Technology Another approach to pushing beyond the limits of Ethernet technology is the development of switching technology A switch bridge Ethernet packets at the MAC address level of the Ethernet protocol transmitting among connected Ethernet or Fas...

Page 6: ... however will used the un used 2 pair of UTP Cat 5 cable for power transmission The power transmission either can be a direct current without any detection protection or can also deploy the new standard IEEE802 3af Two devices required in this technology injector and splitter The injector combine the Ethernet signal and 48VDC currents through UTP cable to the remote end And splitter split out the ...

Page 7: ...ive nodes to guarantee against all possible packet loss The Switch is an unmanaged 10 100 Fast Ethernet Switch that offers solutions in accelerating small Ethernet workgroup bandwidth Other key Features are Auto MDI MDI X on each port for Uplink to another switch hub or repeater Store and forward switching scheme capability As the result of complete frame checking and error frame filtering this sc...

Page 8: ......

Page 9: ...s The surface must support at least 1 5 kg for the Switch Option Confirm with the network administrator for the information of the POE device if the Switch is plan to connect with a 802 3af in line power hub or switch Option The power outlet should be within 1 82 meters 6 feet of the Switch Option Visually inspect the DC power jack and make sure that it is fully secured to the power adapter Make s...

Page 10: ...mponents of the Switch Both the front and rear panels are shown followed by a description of each panel s feature Panel The figures below show the panels of the switch Panels of FSD 504PE Please refer to the LED panel section for detailed information about each of the switch s LED indicators ...

Page 11: ...tch will not work until it is powered If your networked PCs will need to transmit data all the time please consider use an UPS Uninterrupted Power Supply for your Switch either through POE port or DC 12V It will prevent you from network data loss 2 In some area installing a surge suppression device may also help to protect your Switch from being damaged by unregulated surge or current to the Switc...

Page 12: ...ng are LED indicator possibilities for a PC to Switch connection The LINK ACT and 100 LED indicators light green for hookup to 100Mbs LNK ACT lights green while 100 LED off for hookup to 10Mbps speed Hub to Switch A hub 10 or 100Base TX can be connected to the Switch via a two pair Category 3 4 5 UTP STP straight or crossover cable The connection is accomplished from the hub Uplink MDI X or normal...

Page 13: ... indicate it get the power from the remote POE injector And the Switch will start its POST Power on self test process and start to work PoE IP Camera PoE IP Phone PoE Wireless AP FSD 803PE FSD 504PE PoE Injector Switch FGSW 2402PVS Getting the power from central POE injector the FSD 504PE shall works without fear of remote power breakdown As soon as the local PCs also installed with UPS it shall g...

Page 14: ...tors light green for hookup to 100Mbps speed or only LNK ACT light green for hookup to 10Mbps speed Port Speed Duplex Mode After plugging the selected cable to a specific port the system uses auto negotiation to determine the transmission mode for any new twisted pair connection If the attached device does not support auto negotiation or has auto negotiation disabled an auto sensing process is ini...

Page 15: ...P Cat 5 Number of Ports 5 x 10 100Mbps ports DC inputs DC jack DC 12V 500mA max POE port 1 DC48V 150mA max Power Consumption 1 8watt max 6BTU per hour POE Port 1 Port 1 Pint contact of POE port Contact 4 5 7 8 power injection auto detect by IEEE802 3af Temperature Operating 0 50 degree C Storage 10 70degree C Humidity Operating 10 90 Storage 5 90 Dimensions W x D x H mm 93 x 70 x 30 EMI FCC Class ...

Page 16: ...e following table and diagram show the standard RJ 45 receptacle connector and their pin assignments RJ 45 Connector pin assignment Contact MDI Media Dependant Interface MDI X Media Dependant Interface Cross 1 TX transmit Rx receive 2 TX transmit Rx receive 3 Rx receive TX transmit 4 5 Not used 6 Rx receive TX transmit 7 8 Not used Note Contact 4 5 7 8 is not used for port 2 to port 8 And will be ...

Page 17: ...following shows the pin allocation and color of straight cable and crossover cable connection Figure A 1 Straight Through and Crossover Cable Please make sure your connected cable are with same pin assignment and color as above picture before deploying the cables into your network ...

Page 18: ... from this packet comes in the Ethernet Switch will forward this packet to the port where this destination address is located according to the information from address table But if the destination address is located at the same port with this packet comes in when this packet will be filtered Thereby increasing the network throughput and availability Store and Forward Store and Forward is one type ...

Page 19: ...e No packet loss will occur Auto Negotiation The STP ports on the Switch have built in Auto Negotiation This technology automatically sets the best possible bandwidth when a connection is established with another network device usually at Power On or Reset This is done by detect the modes and speeds at the second of both device is connected and capable of Both 10Base T and 100Base TX devices can c...

Page 20: ... POE device cannot provide sufficient power from the injector or 12V DC power is just removed from the DC jack the POE LED will blink a Powered from POE please consult the network administrator if the POE device can provide the sufficient current or not b Powered from 12VDC then POE please remove all the power connection i e both DC plug and port 1 And re connect the port 1 to force the Switch det...

Reviews: