61-359
Function:
Displays or disables SNTP debug information.
Parameters:
adjust
stands for SNTP clock adjustment information;
packet
for SNTP packets,
select
for SNTP clock selection.
Command mode:
Admin Mode
Example:
Displaying debugging information for SNTP packet.
Switch#debug sntp packet
61.3 sntp polltime
Command:
sntp polltime
<interval>
no sntp polltime
Function:
Sets the interval for
SNTP clients to send requests to NTP/SNTP; the “
no sntp polltime
” command cancels the
polltime sets and restores the default setting.
Parameters:
<interval>
is the interval value from 16 to 16284.
Default:
The default polltime is 64 seconds.
Command Mode:
Global Mode
Example:
Setting the client to send request to the server every 128 seconds.
Switch#config
Switch(config)#sntp polltime128