User’s Manual of LRP-822CS/LRP-1622CS
346
6. TROUBLESHOOTING
set up according to instructions in this manual.
■
The Link LED is not lit
Solut
Check the cable connection and remove duplex mode of the LRP Managed Switch
■
Som
stations lo
Solution:
Pleas
gs, or
d / disabled status.
Performance is bad
Solution:
Check the full duplex status of the LRP Managed Switch. If the LRP Managed Switch is set to full duplex and the partner is
set to half duplex, then the performance will be poor. Please also check the in/out rate of the port.
■
Why the Switch doesn't connect to the network
Solution:
1.
Check the LNK/ACT LED on the LRP Managed Switch
2.
Try another port on the LRP Managed Switch
3.
Make sure the cable is installed properly
4.
Make sure the cable is the right type
5.
Turn off the power. After a while, turn on power again
■
100BASE-TX port link LED is lit, but the traffic is irregular
Solution:
Check that the attached device is not set to full duplex. Some devices use a physical or software switch to change duplex
modes. Auto-negotiation may not recognize this type of full-duplex setting.
■
Switch does not power up
Solution:
1.
AC power cord is not inserted or faulty
2.
Check whether the AC power cord is inserted correctly
3.
Replace the power cord if the cord is inserted correctly. Check whether the AC power source is working by
This chapter contains information to help you solve your issue. If the LRP Managed Switch is not functioning properly, make
sure the LRP Managed Switch is
ion:
e stations cannot talk to other
cated on the other port
e check the VLAN settings, trunk settin
port enable
■