83
LEDs in Margay
When the LED is…
LED Name
Off
Green
Amber
Red
Ready
Lamp is on (or no
power)
Source
Source absent
Valid source present
Source absent or not
valid
Lamp
Lamp off
Lamp on
Lamp striking
Lamp failed
Fan
Fan off
Fan is running
Fan failed recently, but
is now running
Fan failed
Lamp disabled
Remote IR
Not receiving IR now
Receiving IR radiation
Door Open (refers to
rear panel and elec-
tronics module door)
No power to electron-
ics
Door closed & rear
panel closed
Lamp enabled
Either door was open,
now closed
Must cycle AC power
to reset and enable
lamp
Either door open
Lamp disabled
Serial Data
No command received
Received any com-
mand
Serial Cmd
Received command
“meant for me”
Lamp Saver
Lamp Saver not active
or lamp is off
Lamp Saver active
Source present
Lamp on
Active
Lamp is cooling
Source present
Lamp will come on
when cooled
Active
Source absent
Lamp off
Optical Engine Status
Optical engine OK
Optical engine fault or
communication fail-
ure
Ballast Status
1
1. At this writing, Ballast Status LED is not implemented, so it is always off.
Lamp off
Lamp on
Ballast fault or com-
munication failure
Ballast Supply
2
2. At this writing, Ballast Supply LED will show Red state only briefly.
High voltage (HV) off
HV on and ready
HV on but not ready
Had to wait more than
10 seconds for ready
state
Summary of Contents for WN-5040-720
Page 1: ...WN 5040 720 User Guide...
Page 2: ......
Page 3: ...i WN 5040 720 Margay 50 Display Wall Unit User Guide 020 0548 00B 29 March 2007...
Page 6: ...iv...
Page 7: ......
Page 14: ...5...
Page 17: ...6...
Page 20: ...9...
Page 24: ...13...
Page 30: ...19...
Page 32: ...21 Electronics module as seen from the front The electronics module door is open...
Page 34: ...23 In Out...
Page 36: ...25...
Page 38: ...27 AC power in and out 1 4 5 3 2 6 No more than 4 115 VAC...
Page 40: ...29...
Page 51: ...40...
Page 54: ...43...
Page 56: ...45...
Page 58: ...47...
Page 66: ...55...
Page 70: ...59...
Page 72: ...61...
Page 74: ...63 ENTER ENTER...
Page 77: ...66...
Page 80: ...69...
Page 82: ...71...
Page 84: ...73...
Page 86: ...75...
Page 95: ...84...
Page 115: ...104 Diagnostics RS232 RS485 Status...
Page 116: ...105 Diagnostics Test Patterns...
Page 117: ...106 Diagnostics Setup Summary...
Page 128: ...117 Starts scanning the input con nectors for the next available source...
Page 131: ...120 7 3 Drawings All dimensions are in inches...
Page 132: ...121...
Page 133: ...122...
Page 134: ...123...
Page 140: ...129...
Page 144: ...133...