Operating procedure
The appliance must function with the suitably closed door.
By moving the control lever can adjust the burning rate
. Experience will show you which settings are
best for your situation.
The air wash system works with the air slide but it is also connected to the quality of the burned
wood
Loading the fuel
-
It is advisable to wait for the fire to be reduced to hot embers before re-loading.
The door should also be opened slowly when re-loading.
The minimum reloading interval for nominal heat output is 45 mn.
-
The logs must be placed on the glowing embers.
-
For a briskly burning fire, there should always be at east two logs in the fire. The fire will
burn better if there are several logs.
-
For a slower burning fire (for example, at night), select larger logs.
-
Always close the loading door
.
Cleaning
-
It is essential to keep the grate free from a heavy build-up of ashes.
-
REMEMBER TO BURN SOLID FUEL CORRECTLY, AlR SHOULD BE ALLOWED TO
FLOW FROM THE ASH PIT AREA THROUGH THE GRATE AND THROUGH THE FUEL.
IF THE GRATE OR ASH PAN ARE CONGESTED, THE PERFOMANCE WILL BE
AFFECTED.
-
Always empty the ash pan at least once a day or whenever it is full of ashes. Never allow the
ash pan to overfill allowing ash to be in contact with the underside of the grate. If this
condition is allowed, the grate will wear out pre-maturely.
Do not open the door of the ash pan, the air inlet could pack the combustion
Maintenance of the chimney
Very important
In order to avoid any incident carried out regularly
If the appliance is regularly used, the chimney should be swept several times per year, together
with the stovepipe connection section.
Safety in case of chimney fire
If the chimney catches fire, you must cut off the flue draught, close the doors and windows,
hatches and keys and call the Fire Brigade without delay.
DO NOT OPEN THE DOOR OF THE APPLIANCE (OR AIR INLET) UNDER ANY
CIRCUMSTANCES.
Eco Minimal 35
N