MALFUNCTION
POSSIBLE CAUSE
I
MEASURE
THE APPLIANCE DOES NOT WORK AT ALL.
1.
The plug of the appliance is not
connected to the socket.
2.
The plug has become loose.
3.
The socket is not supplied with
energy.
4.
The fuse is switched off.
5.
The voltage is too low.
1.
Connect the appliance to the mains
properly.
2.
Check the plug.
3.
Check the corresponding socket by
connecting it with another appliance.
4.
Check the fuse box.
5.
Compare the data on the model
plate with the data of
your
energy
supplier.
THE COMPRESSOR DOES NOT WORK AT ALL.
1.
Incorrect energy supply.
l
1.
Check the energy supply.
THE COMPRESSOR OPERATES FOR TOO LONG.
1.
The appliance has been switched off
for a while.
2.
Too much or too hot food in the
appliance.
3.
Doors opened too often or too long.
1.
The appliance needs some time to
reach the preset temperature.
2.
Remove any hot food.
3.
Do not open the door too often/ too
long.
FORMATION OF ENCRUSTED ICE.
1.
The air outlets may be blocked by
food.
2.
The door is not properly closed.
1.
Store the food in another place.
2.
Close the door properly.