71
~
C
=
V
ENTILATION SLOT
A
B
C
D
E
W
ALL CUPBOARD
➢
min. 760 mm
E
XTRACTOR HOOD
➢
min. 760 mm
min.
50 mm
min.
20 mm
Air inlet
Air outlet
5 mm
The induction hob must be ventilated properly. The air inlet and outlet
must never be blocked or covered.
2.4.2 Installation
S
AFETY INSTRUCTIONS REGARDING THE INSTALLATION
When installing the appliance, ensure optimal heat radiation to maintain the
operating safety.
The wall and the reach of the heat radiation above the worktop must be made of
heat-resistant materials.
To avoid any damage, the sandwich layer and adhesive must resist heat.
Provide an installation opening relevant to the dimensions on the drawings in
chapter 2.3 S
ELECTION OF INSTALLATION EQUIPMENT
/
D
IMENSIONS
. For
installation and use, a
minimum of
50 mm
space shall be preserved around the
installation opening.
The thickness of the worktop must be
at least 30 mm
. Choose heat-resistant
materials for the work top only to avoid any deformation caused by the heat-
radiation of the appliance.
The safety distance between the induction hob and a
wall
cupboard
above must
be
at least
760 mm
.
The safety distance between the induction hob and an
extractor hood
above
must be
at least
760 mm
.