13.9 Digital input 2
Parameters to configure digital input 2.
100 Input function
Select function of digital input 2
Disabled (
Default
) Reset peaks
Enables outputs
Sum total (pulse operation)
Hold
Reset sum (pulse operation)
Tare zero »0« (pulse operation)
Config. lock.
Alarms reset
Gross/net TARE
Reset totalizer (pulse operation)
101 Contact type
Select inactive contact for digital input 2
Normally open
(
Default
) Executes function with closed contact
Normally closed Executes function with open contact
13.10 Graphic
Parameters to configure trend and bar graph management.
105 Graphic type
Select the type of graph to be visualized on the relevant page
Trend (
Default
)
Bar graph
106 Lower limit
Trend or bar graph lower limit
-999999 [Digit
2
],
Default
: 0.
107 Upper limit
Trend or bar graph upper limit.
-999999 [Digit
2
],
Default
: 1000.