Installation, use and maintenance
M0546
20
/60
14 INSTALLATION
FOREWORD
CUBE B.SMART can be installed outdoors However, it is advisable to shelter
it under a canopy to ensure a longer life and provide more comfort when
refilling in bad weather. The installation of the dispenser must be carried
out by specialised personnel and carried out according to the instructions
provided in this chapter. If CUBE B.SMART is not sheltered under a canopy,
a “display cover” is provided as protection for the display and keypad.
WARNING
Staff
authorised for
installation
All installation operations must be performed only by competent and
authorised staff, who must:
Install the system in a dry, well-ventilated place;
Properly install the accessories necessary for the correct operation of the
equipment.
Use solely the accessories provided with the system.
IMPORTANT
The use of unsuitable accessories not provided with the system is strictly
prohibited. Piusi S.p.A. accepts no responsibility for harm to persons,
property or the environment due to failure to observe this instruction.
THE UNIT IS FOR PROFESSIONAL USE ONLY.
The unit must be installed in an adequately lit location, in compliance with
the regulations in force.
The unit has been designed to be used in a dry place. If it is installed
outdoors, provide adequate protective covering.
The motors are not explosion-proof. Do NOT install in places with
explosion hazard.
14.1 DISPENSER POSITIONING
The positioning of CUBE B.SMART must ensure that:
- Removable panels can be easily removed for access to internal components
when necessary.
- The maximum distances and differences in level between the station and
the tank are respected
- A correct and solid fixing of the casing to the ground on a horizontal plane
is possible.
The positioning of the station determines the following parameters, which
characterize each installation:
Hp: Priming height
Ls: Total length of the suction pipes - from the bottom valve to the station
(in metres).
The following restrictions must be observed for the stations to function
properly:
Hp max: no more than 3 metres
Ls max: no more than 15 metres
Summary of Contents for CUBE B.SMART
Page 1: ...CUBE Bulletin M0546 EN_01 Installation use and maintenance EN ...
Page 2: ...Installation use and maintenance M0546 2 60 Bulletin M0546 ENGLISH ...
Page 56: ...Installation use and maintenance M0546 56 60 24 EXPLODED VIEWS ...
Page 58: ...Installation use and maintenance M0546 58 60 note ...
Page 59: ......