Page 7
For technical questions, please call 1-888-866-5797.
Item 61382
SAFET
y
Op
ERA
TION
M
AINTENAN
c
E
SETU
p
Figure
c
:
Stationary
Air Supply Setup
N
L
L
O
M
C
C
Non-lubricated
Tools
Lubricated Tools
H
I
I
J
J
K
H
F
G
E
Slope
F
F
B
B
A
A
C
D
Description
Function
A
Vibration Pads
For noise and vibration reduction
B
Anchor Bolts
Secures air compressor in place
C
Ball V
alve
Isolates sections of system for maintenance
D
Isolation Hose
For vibration reduction
E
Main
Air Line - 3/4″ minimum recommended
Distributes air to branch lines
F
Ball V
alve
To drain moisture from system
G
Branch
Air Line -1/2″ minimum recommended
Brings air to point of use
H
Air Hose
Connects air to tool
I
Filter
Prevents dirt and condensation from damaging tool or workpiece
J
Regulator
Adjusts air pressure to tool
K
Lubricator (optional)
For air tool lubrication
L
Coupler and Plug
Provides quick connection and release
M
Leader Hose (optional)
Increases coupler life
N
Air Cleaner / Dryer (optional)
Prevents water vapor from damaging workpiece
O
Air
Adjusting V
alve (optional)
For fine tuning airflow at tool
Summary of Contents for 61382
Page 1: ......