9
DOC_IPA_CONTROL_EXACT_ENG_20190122
▬
If the dampening solution temperature drops below the set
minimum temperature during the measuring phase, a new
heating phase and then a new measuring phase will begin.
▬
Under extreme conditions (very low dampening solution
temperature and low ambient temperature), it is possible that
the maximum allowable heating time of 150 seconds will be
reached. In this case, the measurement with the now pre-
heated dampening solution will need to be manually restarted.
A corresponding message will be shown on the display.
▬
A dampening solution temperature above 25 °C can similarly
not be measured. In this case, the measurement should be
restarted with a new, cooler dampening solution sample
taken from the printing press.
5. Adjustment, Diagnosis
▬
Selecting “Service“ in the main menu opens the service menu
with the items:
• Language
• Device Test
• Parameters
Under “
Language
“ the operating language (English/German)
can be chosen.
▬
Selecting “
Device Test
“ performs a function test of the device.
The current measured values for the gas sensor voltage and
the temperature are shown. The motor in the measuring head
is also started (audible). The function test is ended by press-
ing the on/off button.
▬
Under “
Parameters
“ is an operating time counter for the
individual device components.
▬
The menu items “
Device Test
“ and “
Parameters
“ are intended
to be used for possible diagnoses or service issues and are not
needed for normal operation.