![Pioneer X-HM71-K Service Manual Download Page 35](http://html.mh-extra.com/html/pioneer/x-hm71-k/x-hm71-k_service-manual_1557962035.webp)
35
X-HM81-K
5
6
7
8
5
6
7
8
A
B
C
D
E
F
6.3 CHECKING THE LCD
To enter Test mode, select the NETWORK function, then press the ESC then FRM/TIM keys.
TEST MODE will be displayed. (Although TEST MODE is displayed even if the CD or Tuner function
is selected, LCD checking is not possible with those functions selected.)
LCD checking is possible in Test mode for use on the production line.
To quit TEST MODE, perform one of the following operations:
1. Switch the input function.
2. Turn the unit off.
3. Perform factory setting.
How to perform LCD checking
Each time the 1 key on the remote control unit supplied with the product is pressed, the screen is changed as shown below
Ramp > Black > White > Red > green > Blue
If the 0 key is pressed, the screen will return to that of playback.
[Screens to be displayed]