6.8 LIST OF RS-232C COMMANDS
RS-232C commands can be used in Service Factory mode.
Before using RS-232C commands, it is necessary to change the factory presetting. See "6.3. USING RS-232C COMMANDS."
Command Operation
Remarks
A
ABL
Adjusting power consumption
B
BCP
Transmitting the backup data to the DIGITAL Assy
BAVS00
Setting the power supply for the DTB antenna to 0 V
BAVS02
Setting the power supply for the DTB antenna to 5 V
BSL
Adjusting side mask B
BYG
BY GAIN
C
CNG
Clearing MR NG information
CPC
Clearing the power-on counter
CPD
Clearing power-down information
CSD
Clearing shutdown information
CTM
Clearing the modification log
D
OSDS01
Turning on the on-screen display
While the OSDSOI command is in force, the duration of on-screen display is unlimited.
OSDS00
Turning off the on-screen display
On-screen display is prohibited.
DRF
Turning off the power for the drive system
DRN
Turning on the power for the drive system
DW*
Decreasing the adjustment value by *
*: 1-9, 0 (0 means 10), or F (making the adjustment value the minimum)
E
EDWS00
Prohibiting writing of EDID data
EDWS01
Permitting writing of EDID data
F
F50
Video 50-Hz sequence
F60
Video 60-Hz sequence
F61
PC 60-Hz sequence
F70
PC 70-Hz sequence
F72
Video 72-Hz sequence
F75
Video 75-Hz sequence
FAY
Turning Service Factory mode on
FAJ
Determining the adjustment values for the unit
FAN
Turning Service Factory mode off
Focus OFF
Focus ON
Final set up
FCSS00
FCSS01
FST
The GUI equivalent to that usually displayed when the power is turned on is displayed.
G
The GET-group commands are effective at any time, including during Standby mode.
GAJ
Obtaining the adjustment values for the panel
GDI
Command to obtain Status
GA2
Obtaining the various adjustment values (Add Vrn to GAJ)
GMM
Switching the gamma levels
Setting value: 000-007
GNG
Obtaining NG data of the MR
GNM
Obtaining the serial No. of the MR
GNP
Obtaining the serial No. of the panel
GPC
Obtaining the P ON COUNTER value
GPD
Obtaining power-down information
GPR
Obtaining the PANEL REVISE data
GPM
Obtaining the PULSE METER data
GPW
Obtaining the PANEL W/B data
GS1
Obtaining the version data for each device
GS2
Obtaining data on various operations
GS6
Obtaining the any version
GSD
Obtaining shutdown information
Adjusting side mask G
GYG
GY GAIN
GSL
CHM
Clearing the hour meter
CPM
Clearing the pulse meter
This command is effective even during Standby mode.
PDP-R05XE only
PDP-R05XE only
Summary of Contents for PDP-R05E
Page 13: ...PDP R05E 13 5 6 7 8 5 6 7 8 C D F A B E ...
Page 55: ...PDP R05E 55 5 6 7 8 5 6 7 8 C D F A B E Signal 5 9 B 2 9 B 3 9 B 5 9 B 2 9 3 9 B B 1 9 1 2 ...
Page 61: ...PDP R05E 61 5 6 7 8 5 6 7 8 C D F A B E B 4 9 Basic PDP R05FE ...
Page 67: ...PDP R05E 67 5 6 7 8 5 6 7 8 C D F A B E 8 9 B B 7 9 ...
Page 69: ...PDP R05E 69 5 6 7 8 5 6 7 8 C D F A B E B 8 9 ...
Page 72: ...PDP R05E 72 1 2 3 4 1 2 3 4 C D F A B E 3 24 MDR ASSY E MDR ASSY AWZ6948 E ...
Page 73: ...PDP R05E 73 5 6 7 8 5 6 7 8 C D F A B E E CN7402 A 11 12 ...
Page 75: ...PDP R05E 75 5 6 7 8 5 6 7 8 C D F A B E F CN8658 B 5 9 Basic PDP R05FE Basic PDP R05FE ...
Page 76: ...PDP R05E 76 1 2 3 4 1 2 3 4 C D F A B E 3 26 FRONT ASSY G ...
Page 79: ...PDP R05E 79 5 6 7 8 5 6 7 8 C D F A B E H CN8656 B 5 9 ...
Page 81: ...PDP R05E 81 5 6 7 8 5 6 7 8 C D F A B E I 1 6 ...
Page 83: ...PDP R05E 83 5 6 7 8 5 6 7 8 C D F A B E I 2 6 ...
Page 84: ...PDP R05E 84 1 2 3 4 1 2 3 4 C D F A B E 3 30 TUNER BOARD ASSY 3 6 I 3 6 ...
Page 85: ...PDP R05E 85 5 6 7 8 5 6 7 8 C D F A B E I 3 6 I 3 6 TUNER BOARD ASSY AWE1301 ...
Page 87: ...PDP R05E 87 5 6 7 8 5 6 7 8 C D F A B E I 4 6 B 5 9 CN8662 ...
Page 89: ...PDP R05E 89 5 6 7 8 5 6 7 8 C D F A B E I 5 6 ...
Page 91: ...PDP R05E 91 5 6 7 8 5 6 7 8 C D F A B E I 6 6 CN6951 7 12 A ...
Page 107: ...PDP R05E 107 5 6 7 8 5 6 7 8 C D F A B E B SIDE B Y ANP2088 B CN8502 CN8656 CN8651 ...
Page 176: ...PDP R05E 176 1 2 3 4 1 2 3 4 C D F A B E 49 TP7710 ...