1.2 CHARGED SECTION AND HIGH VOLTAGE GENERATING POINT
Fig. High Voltage Generating Point (Rear view)
42 SCAN B Assy
Conductive plate X
42 Y DRIVE Assy
42 X DRIVE Assy
POWER SUPPLY Unit
AC inlet
Power switch
42 SCAN A Assy
: Part is the High Voltage Generating Points
other than the Charged Section.
The places where the commercial AC power is used without
passing through the power supply transformer.
If the places are touched, there is a risk of electric shock. In
addition, the measuring equipment can be damaged if it is
connected to the GND of the charged section and the GND of the
non-charged section while connecting the set directly to the
commercial AC power supply. Therefore, be sure to connect the
set via an insulated transformer and supply the current.
1. Power cord
2. AC inlet
3. Power switch
4. Fuse (In the POWER SUPPLY Unit)
5. STB transformer and Converter transformer
(In the POWER SUPPLY Unit)
6. Other primary side of the POWER SUPPLY Unit
: Part is Charged Section.
Charged Section
The places where voltage is 100 V or more except for the charged
places described above. If the places are touched, there is a risk of
electric shock.
The VSUS voltage remains for several minutes after the power to
the unit is turned off. These places must not be touched until
about 10 minutes after the power is turned off, or it is confirmed
with a tester that there is no residual VSUS voltage.
If the procedures described in “5.6.1 PANEL DRIVE-POWER
ON/OFF FUNCTION” are performed before the power is turned
off, the voltage will be discharged in about 30 seconds.
POWER SUPPLY Unit........................................................(200 V)
42 X DRIVE Assy................................................................(200 V)
42 Y DRIVE Assy...............................................(–230 V to 500 V)
42 SCAN A Assy.................................................(–230 V to 500 V)
42 SCAN B Assy.................................................(–230 V to 500 V)
High Voltage Generating Point
Summary of Contents for PDP-4280HD
Page 10: ...PDP 4280HD 10 1 2 3 4 1 2 3 4 C D F A B E 2 2 SPECIFICATIONS Dimensions ...
Page 11: ...PDP 4280HD 11 5 6 7 8 5 6 7 8 C D F A B E 2 3 PANEL FACILITIES Front Section ...
Page 12: ...PDP 4280HD 12 1 2 3 4 1 2 3 4 C D F A B E Rear Section ...
Page 13: ...PDP 4280HD 13 5 6 7 8 5 6 7 8 C D F A B E Remote Control Unit ...
Page 19: ...PDP 4280HD 19 5 6 7 8 5 6 7 8 C D F A B E ...
Page 20: ...PDP 4280HD 20 1 2 3 4 1 2 3 4 C D F A B E 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Page 22: ...PDP 4280HD 22 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL WIRING DIAGRAM 2 2 ...
Page 23: ...PDP 4280HD 23 5 6 7 8 5 6 7 8 C D F A B E ...
Page 35: ...PDP 4280HD 35 5 6 7 8 5 6 7 8 C D F A B E ...
Page 168: ...PDP 4280HD 168 1 2 3 4 1 2 3 4 C D F A B E 10 6 PANEL CHASSIS SECTION ...
Page 172: ...PDP 4280HD 172 1 2 3 4 1 2 3 4 C D F A B E 10 8 PDP SERVICE ASSY 428 Exterior Section ...