(8) No pictures
[
(Caution)
The voltage outputs of Vs = 170V and Vd = 64V, 5Vdc are always generated, but the
LED is not flashing or lighting for alarming. However, the voltage values can differ according to the
MODULE
.]
YES
YES
NO
The AD connector or the PDP is fault.
The MAIN PWB is fault.
No picture is displayed.
Does the priming glimpse?
NO
The PDP is fault.
Make the setting of OFF
→
ON
for the main power supply.
(
Refer to P7-1 "HOW TO DIAGNOSE THE PDP MODULE".
)
(
Refer to P7-1 "HOW TO DIAGNOSE THE PDP MODULE".
)
When the AD connector is disconnected, is
the LVDS signal normally output to each
pin of the AD connector? (For more details
of the signal, refer to the descriptions about
the connector pins.)