7.1.10 NOTE ON REPLACEMENT OF THE SDRAM
Note when replacing the SDRAM
When replacement of the SDRAM (IC1201 or IC1221) on the MAIN Assy is required, identify the manufacturer of the SDRAM.
If the SDRAM that needs replacement was manufactured by HYNIX, both IC1201 and IC1221 must be replaced at the same
time.
SDRAMs for service are manufactured by SAMSUNG.
How to identify the manufacturer
Confirm the name of the manufacturer stamped on the surface of the part.
Measures to be taken
1
If the SDRAM that needs replacement was manufactured by HYNIX:
Replace both IC1201 and IC1221 at the same time.
2
If the SDRAM that needs replacement was manufactured by SAMSUNG:
Replacement of only the defective SDRAM (IC1201 or IC1221) is possible.
Possible malfunctions
If SDRAMs made by different manufacturers are mounted on the MAIN Assy, the following malfunctions may occur:
1
The power does not come on.
2
High-speed dubbing disabled
3
Other malfunctions related to the SDRAM
By HYNIX (replacement of both SDRAMs required)
By SAMSUNG (replacement of only the defective SDRAM possible)