6. ADJUSTMENT
6.1 TEMPO ZERO POINT ADJUSTMENT
Zero Point ADJ.
POWER ON
POWER OFF
Set the TEMPO knob to the
mechanical center "0."
Check that the TEMPO
indication shows 0.00%.
OK
NG
Perform fineadjust-
ment with the
VR1402.
Repeat the procedure until the TEMPO indication shows 0.00%.
No adjustment required
Note:
Because the value of the adjusted voltage is read only when the unit is turned on, if the TEMPO indication does not
become 0% at the slider center after adjustment, turn off the power, and perform fineadjustment again. (Repeat the
sequence of fineadjustment, power on, check, power off, and fine-adjustment.)
When adjusting the VR1402 (Zero point adj.), adjust it from the hole on the foil side with the SLDB Assy attached to the
control panel.
TEMPO indication (%)
TEMPO knob "0"
Jig
Exchange the SLIDER VR
VR1402
(Zero Point ADJ.)
Precise screwdriver (small)
Necessary Adjustment Points
Adjustment and Check Points
When
Adjustment points
VR1402
(Zero Point ADJ.)
SLDB ASSY
Control panel