5.8

 

NUMBER  OF  LIFTING  TOOLS  REQUIRED  FOR  LIFTING  THE  WALLS  DEPENDING 
ON THE SIZE AND WEIGHT OF THE LIFTED WALLS 

To  ensure  the  safety  and  stability  of  the  wall  during  lifting,  it  is  necessary  to  lift  the  walls 
by at least two lifting tools at the same time. Specific number of lifting tools depends on lifted 
wall parameters, such as its weight and dimensions. 

To avoid an excessive wall deflection between the lifting tools, there is a limit of maximal 
permitted distance between the lifting tools and their distance from wall ends, as it is shown 
in Table 2 below. 

 

Table 2

 

NUMBER OF LIFTING TOOLS NECESSARY TO LIFT THE WALLS DEPENDING ON THEIR SIZE 
AND WEIGHT. 

TOP 

PROFILE 

HEIGHT 

 

[mm] 

WALL LENG 

 

[m] 

WALL WEIGHT (kg) WITH SHEATING

 

DISTANCE 

FROM WALL 

ENDS 

MAX.

 

 

[m] 

DISTANCE 

BETWEEN 

LIFTERS 

MAX.

 

 

[m] 

NONE

 

 

[kg] 

15 mm  

OSB desk 

 

[kg] 

60 mm WFB 

or 

12,5 mm PFB 

 

[kg] 

 

100 mm WFB 

 

[kg] 

#

 

 

A

 

 

 

 

B

 

C

 

140 

200 

285 

370 

483 

1,0 

3,00 

160 

250 

340 

430 

550 

1,0 

3,00 

200 

290 

365 

440 

540 

1,0 

3,00 

140 

320 

450 

580 

753 

1,5 

4,00 

160 

340 

480 

620 

807 

1,5 

4,00 

200 

420 

545 

670 

837 

1,5 

4,00 

140 

420 

590 

760 

987 

2,0 

5,00 

160 

490 

640 

790 

990 

2,0 

5,00 

200 

550 

705 

860 

1067 

2,0 

5,00 

140 

10 

490 

715 

940 

1240 

2,0 

3,75 

160 

540 

760 

980 

1273 

2,0 

3,75 

200 

590 

810 

1030 

1323 

2,0 

3,75 

140 

12 

570 

840 

1110 

1470 

2,0 

4,75 

160 

610 

880 

1150 

1510 

2,0 

4,75 

200 

730 

980 

1230 

1563 

2,0 

4,75 

 

    

   2 lifting Tools             3 lifting tools Tools              4 lifting Tools 

 

#  DIMENSIONS LITERAL MARKING, SEE CHAPTER 5.7 
 
NOTE 

 ALL MENTIONED VALUES ARE INDICATIVE ONLY! 

It is considered with wall height 2900 mm, Wooden Fiber Board (WFB) with 265 kg/m

density 

and OSB desks (4

th

 class) with 620 kg/m

3

 density. Or eventually with Plaster Fiber Board (PFB) 

1250 kg/m

3

 density. All the values given in the table have an informative character and could 

be used for a guidance only. 

Summary of Contents for JACKIE L

Page 1: ...24 rev 10 PINNIUM s r o Za Pazdernou 2573 397 01 P sek CIN 109 01 442 EU VAT No CZ10901442 USER S G U I D E PINNIUM s r o Residence Za Pazdernou 2573 8 397 01 P sek EU VAT No CZ10901442 Contact pinniu...

Page 2: ...JACKIE L USER S GUIDE Edition 24 January 2022 2 28 Ev n 2 20220124 rev 10 PINNIUM s r o Za Pazdernou 2573 397 01 P sek CIN 109 01 442 EU VAT No CZ10901442...

Page 3: ...intain and evaluate the risks that may arise during operation of the Tool If you are not sure that you understood the information correctly or have questions about its usage contact us using the conta...

Page 4: ...JACKIE L USER S GUIDE Edition 24 January 2022 4 28 Ev n 2 20220124 rev 10 PINNIUM s r o Za Pazdernou 2573 397 01 P sek CIN 109 01 442 EU VAT No CZ10901442...

Page 5: ...Y REGULATION DIN EN 336 2013 12 10 5 5 LIFTING STEPS qUICK OVERVIEW 11 5 6 WALL LIFTING TECHNIQUE FROM HORIZONTAL POSITION 12 5 7 WALL RELEASING FROM THE LIFTING TOOL 19 5 8 NUMBER OF LIFTING TOOLS RE...

Page 6: ...JACKIE L USER S GUIDE Edition 24 January 2022 6 28 Ev n 2 20220124 rev 10 PINNIUM s r o Za Pazdernou 2573 397 01 P sek CIN 109 01 442 EU VAT No CZ10901442...

Page 7: ...user s guide and being sure you understood correctly all the content Keep this manual for future utilization Pay special attention to the safety instructions Failure to observe the safety rules may ca...

Page 8: ...ATELY AT LEAST TWO LIFTERS ARE ALWAYS NEEDED TO BE USED FOR LIFTING ONE WALL AT THE SAME TIME 5 1 TECHNICAL PARAMETERS Maximum load capacity vertical max 268 kg Dimensions without main rod 327 x 185 x...

Page 9: ...Pazdernou 2573 397 01 P sek CIN 109 01 442 EU VAT No CZ10901442 5 2 LIFTING TOOL PARTS 5 3 TERMS USED FOR WALLS AND ITS PARTS There are described terms used for walls and its parts see Figure 3 1 Lift...

Page 10: ...cording to DIN EN 336 2013 12 We highly recommend to use a new rising joist to lift each wall to ensure trouble free operation during the lifting ATTENTION IF DIMENSIONS OF THE RISING JOIST ARE OUT OF...

Page 11: ...Wall horizontal position 2 Lifting the Wall using the Jackie Tool 3 Lifting tool limit 80 85 4 Securing the wall against overfall illustration 5 Lifting the wall from 85 to 90 by hand Securing the wal...

Page 12: ...ective floor 3 OPTIONS OF WALL SECURING AT THE BOTTOM EDGE a SECURING THE BOTTOM EDGE OF THE LIFTED WALL USING DOOR HINGES Securing the wall against unwanted sliding using the door hinges is shown in...

Page 13: ...is already fixed to the baseplate c SECURING THE BOTTOM EDGE OF THE LIFTED WALL USING ANGLED SCREWS Securing the wall against unwanted sliding is done by joining the lower plate with the bottom plate...

Page 14: ...ns of double top plate and the wall use more lifting tools Determine the number of lifting tools according to the wall s dimensions and weight see Table 2 in Chapter 5 8 This will reduce excessive def...

Page 15: ...h the two flaps of the Tool up to the touch with the floor 2 Put the lifting Tool together with the rising joist inserted inside on the heel Do not fix the heel to the floor yet Check whether the risi...

Page 16: ...ool position Figure 12 between the wall studs cripples Incorrect lifting Tool position Figure 13 under the wall studs cripples Grab hold of main rod by your hand and check whether the rod is properly...

Page 17: ...on the floor b Bottom plates are firmly fixed to the ground and secured against any movement c Lifting Tool with the rising joist and the heel are well positioned under the lifted wall and the wall is...

Page 18: ...ing and manipulation with the lifting Tool during the remaining angle 5 10 is shown in the Chapter 5 5 and 5 7 NOTICE The lifting Tool contains two levers Main rod O and auxiliary lever P Main lifting...

Page 19: ...sure that the length of the rising joist is sufficient and the joist has a necessary overlap as it is shown at Figure 18 c Get the wall into the vertical position eventually check the verticality usin...

Page 20: ...T kg WITH SHEATING DISTANCE FROM WALL ENDS MAX m DISTANCE BETWEEN LIFTERS MAX m NONE kg 15 mm OSB desk kg 60 mm WFB or 12 5 mm PFB kg 100 mm WFB kg A B C 140 4 200 285 370 483 1 0 3 00 160 250 340 430...

Page 21: ...RECOMMENDED LIFTING TOOL POSITIONS FOR SEVERAL WALLS DIMENSIONS Each position of the Lifting Tool below can be considered as a position for workers also Therefore at least two workers are always requi...

Page 22: ...aintain a sufficient distance to ensure their own safety Make sure that the load does not come into contact with other obstacles Do not place multiple loads on the Lifting Tool at once Do not allow th...

Page 23: ...n the construction site such as goggles hearing protection helmets safety shoes etc Never perform maintenance while the Tool is in use Do not overload the Tool or any accessories If you notice any unu...

Page 24: ...to their use Demonstrably unprofessional use of the goods in contradiction with the operating instructions Arbitrarily unauthorized done modifications to the Tool and its Equipment Mechanical damage c...

Page 25: ...JACKIE L USER S GUIDE Edition 24 January 2022 25 28 Ev n 2 20220124 rev 10 PINNIUM s r o Za Pazdernou 2573 397 01 P sek CIN 109 01 442 EU VAT No CZ10901442 9 EC DECLARATION OF CONFORMITY...

Page 26: ...JACKIE L USER S GUIDE Edition 24 January 2022 26 28 Ev n 2 20220124 rev 10 PINNIUM s r o Za Pazdernou 2573 397 01 P sek CIN 109 01 442 EU VAT No CZ10901442 NOTES...

Page 27: ...JACKIE L USER S GUIDE Edition 24 January 2022 27 28 Ev n 2 20220124 rev 10 PINNIUM s r o Za Pazdernou 2573 397 01 P sek CIN 109 01 442 EU VAT No CZ10901442...

Page 28: ...PINNIUM s r o Za Pazdernou 2573 397 01 P sek CIN 109 01 442 EU VAT No CZ10901442...

Reviews: