Pinnacle Products International, Inc.  Residential Dehumidifier Owners’ Manual

Safety Information

WARNING:

1.  This unit is designed for indoor use only.  Do not expose to elements or allow to become 

wet.

2.  To guard against electric shock while operating, do not allow dehumidifier to come in contact

with other grounded objects such as pipes, radiators, etc.

3.  Do not use this unit next to a source of heat such as a radiator, dryer, etc., an area where oil

or water is likely to splash, an area directly exposed to sunlight, near a bath, shower or swim-
ming pool, or in a greenhouse.

4.  Always store the unit upright in order to maintain the compressor in a proper working condition.

Leave the unit upright for at least 24 hours prior to operating.

5.  BEFORE moving, storing, and/or changing operating locations, be sure the dehumidifier is

turned off, unplugged AND the water tank is empty.

6.  Operate only on 115 volt 60 Hz (cycle) current with a minimum of a 15 amp circuit.

7.  Before operating always check dehumidifier for loose or damaged parts.  Inspect power cord

for any damage.  Never use dehumidifier if any parts are damaged or missing.  There are no
user serviceable parts.

8.  DO NOT use with an extension cord. Use only with a grounded 3 prong outlet furnished on the

dehumidifier’s power cord.  Always keep power cord away from heat, oil, and sharp edges. 

9.  Disconnect dehumidifier from power source when not in use, before servicing and when clean-

ing or repairing.

10. Repair of this dehumidifier should be done by a qualified electrician.

11. In case of power failure, turn dehumidifier off at control panel to prevent unexpected restarting

and possible component damage.

12. Keep children away from dehumidifier at all times.

IMPORTANT:  

READ ALL INSTRUCTIONS CAREFULLY BEFORE USE OF THIS

DEHUMIDIFIER.  FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD
RESULT IN SERIOUS PERSONAL INJURY AND / OR PROPERTY DAMAGE.

FOR BEST RESULTS: 

KEEP ALL WINDOWS,  DOORS

AND OTHER OPENINGS

CLOSED.

Residential

Dehumidifier

Summary of Contents for TT-40P-DH

Page 1: ...manual before starting this dehumidifier Improper use of this dehumidifier can cause serious injury Keep this manual for future reference This unit is fitted with an auto defrosting opera tion and st...

Page 2: ...y on 115 volt 60 Hz cycle current with a minimum of a 15 amp circuit 7 Before operating always check dehumidifier for loose or damaged parts Inspect power cord for any damage Never use dehumidifier if...

Page 3: ...or Button will change the humidity setting see Figure 3 on Page 4 3 Pressing the Continue Button will put the unit into continuous dehumidifying mode at this point the Humidity or Button will become i...

Page 4: ...is pressed and the fan is on low NOTE This unit has an automatic shut off If the bucket is full or is not replaced correctly the unit will not start and will display a P2 warning Please be sure bucket...

Page 5: ...Cleaning the Unit Enclosure 1 Use a soft clean cloth to wipe the surface Do not use water as this may cause an electrical shock Cleaning the Water Tank 1 Wash the tank using warm water about 100 F wi...

Page 6: ...rol Box Cover 35 005 0600 16 Compressor 35 006 0100 17 Compressor Bracket 35 006 0200 18 Compressor Capacitor Cover 35 006 0300 19 Compressor Capacitor 35 006 0400 20 Base Pan 35 007 0100 21 Caster 35...

Page 7: ...oom humidity level is lower than unit setting Press the Humidity Button to lower the humidity set ting below room humidity level See Page 4 Decreased Performance 1 Blocked Air Filter Wash Air Filter 2...

Page 8: ...reight pre paid If Pinnacle Products International Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of...