Pinnacle Climate Master MH-515-120 User'S Manual & Operating Instructions Download Page 1

Model Numbers

MH-515-120 / MH-53-240

CONSUMER: READ AND SAVE THESE INSTRUCTIONS

Factory ID: 514

USE THIS HEATER ONLY AS DESCRIBED IN THIS MANUAL. ANY 

OTHER USE NOT RECOMMENDED BY THE MANUFACTURER 

MAY CAUSE FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS. 

4003787

WARNING

Safety Information

FIRE OR EXPLOSION MAY OCCUR! 

Heater has hot arching or 

sparking parts inside. Do not use it in areas where gasoline, paint 

or flammable liquids are used or stored.

RISK OF FIRE. 

To prevent a possible fire, Do not block intakes or 

exhaust in any manner. Do not use on soft surfaces, like a bed where 

openings may become blocked. Heater must be kept clear of all 

obstructions. Maintain a 3 foot minimum clearance from front and 12 inches from sides and rear.  

Heaters must be kept clean of lint, dirt, and debris (see maintenance instructions Page 6).

RISK OF FIRE. DO NOT 

use heater with extension cord. Plug the 

MH-515-120 heater directly into a 120VAC receptacle. Plug the 

MH-53-240 heater directly into a 208-240VAC receptacle.

OVERHEATING OR FIRE MAY OCCUR. 

Do not place heater 

behind doors.

BURN HAZARD. 

This heater is hot when in use. To avoid 

burns, 

do not let bare skin touch hot surfaces. If provided, use handles 

when moving the heater

RISK OF ELECTRIC SHOCK OR INJURY. 

Do not run cord under 

carpeting, Do not cover cord with throw rugs, runners or similar 

coverings. Do not route cord under furniture or appliances. Arrange 

cord away form the traffic area where it will not cause a tripping hazard. Do not operate 

any heater with a damaged cord or plug, or after heater malfunctions, or has been dropped 

or damaged in any manner. Discard heater, or return to authorized service facility for 

examination and / or repair.

WARNING
WARNING

WARNING
WARNING
WARNING

WARNING

RISK OF ELECTRICAL SHOCK. 

Connect to properly 

grounded outlets only. Do not insert or allow foreign 

objects to enter any ventilation or exhaust opening as 

this may cause an electric shock or fire, or damage the heater. Unplug heater 

before performing any maintenance or when not in use,  To disconnect heater, 

turn control to low, then remove plug from outlet.

WARNING

1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (800) 779-3267

Fax: 320-251-2922 • Web: www.masterindustrialproducts • Email: [email protected]

© 2017 Pinnacle Climate Technologies, Inc. MAEA-400

User’s Manual & Operating Instructions

TURBO ELECTRIC FAN HEATER

Summary of Contents for Master MH-515-120

Page 1: ...ater is hot when in use To avoid burns do not let bare skin touch hot surfaces If provided use handles when moving the heater RISK OF ELECTRIC SHOCK OR INJURY Do not run cord under carpeting Do not co...

Page 2: ...nvalids Do not use outdoors This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate heater where it may fall into a bathtub or other water container Do...

Page 3: ...Settings 1 1 Specifications subject to change without notice Features MH 515 120 MH 53 240 Figure 1 Handle Adjustment Knob Thermostat Knob Function Selector Power Light Front Guard Fan Heater Coil 2...

Page 4: ...es Inc Turbo Electric Fan Heater User s Manual Assembly Instructions What s In The Box Upper Handle Bracket 2 Inner Lower Handle Bracket 2 Outer Lower Handle Bracket 2 Adjustment Knob 2 24 mm Bolts 16...

Page 5: ...leg frame with lower inner bracket 2 Attach lower outer bracket to lower inner bracket using screws 3 Align lower inner bracket with side support 4 Attach side supports to heater using tilt adjustment...

Page 6: ...F 85 C Caution Light The Caution Light will illuminate when the Overheat Safety Control is activated The heating element will be shut off until the unit has cooled to a safe level The fan will contin...

Page 7: ...ater Operation Grounding Instructions MH 515 120 This heater is for use on 120 Volts The cord has a plug as show at A below An adapter as shown at C is available for connecting three blade grounding t...

Page 8: ...ing 1 Heater is operating correctly Fan speed stays the same when changing settings 1 Fan speed stays constant Setting changes amount of heat output only 1 Heater is operating correctly Heating elemen...

Page 9: ...ition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Climate Technologies Inc disclaims al warranties for products...

Page 10: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 800 779 3267 Fax 320 251 2922 Web www masterindustrialproducts com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Reviews: