background image

                                                                                                                                                

 

-1- 

WFM500 

Installation Instructions 
Инструкция по установке 
Instrucciones de Instalación

 

הנקתה תוארוה 

English,

 

Русский, Español,

 

תירבע

 

            

 

 

 

1  Antenna 
2  Reset Button  
3  WAN Socket (Not in Use) 
4  LAN Socket 
5  LED 
6  Mounting Holes 
7  DC IN 
8  Ethernet Socket 
9  +/- Voltage Terminals 

 

1  Антенна 
2  Кнопка Reset 
3  Подключение WAN (Не используется) 
4  Подключение LAN 
5  Светодиод 
6  Монтажные отверстия 
7  Вход питания DC 
8  Сетевое подключение (Ethernet) 
9  Клеммы питания +/- 

 

1  Antena 
2  Botón de reinicio (Reset) 
3  Conector WAN (Fuera de uso) 
4  Conector LAN 
5  LED 
6  Orificios de montaje 
7  Entrada DC 
8  Conector Ethernet 
9  Terminales para v/- 

 

1

 

הנטנא

 

2

 

לוחתא רותפכ

 

 

3

 

 עקש

WAN

 

)שומישב אל(

 

4

 

 עקש

LAN

 

5

 

תירונ

 

6

 

 ירוח

ה

ת

נק

ה

 

7

 

 חתמ תסינכ

DC

 

8

 

תשר עקש

 

9

 

ירוביח

 

-

 +/

םיאלג חתמ

 

WFM500 Ethernet to Wi-Fi Adapter 

The WFM is an Ethernet to Wi-Fi adapter, which enables connecting the 

FORCE

 

Series

 intruder alarm systems to wi-fi network. 

The WFM is connected to the control panel’s detector’s voltage. The adapter is supplied with backup power from the control panel

1

, and 

is configured using a web browser.  
For the programming information, see the

 FORCE

’s Installation guide (P/N: 4410459). 

.Technical specifications 

 

Network standard: 

o

 

Wireless: IEEE 802.11n, IEEE 802.11g. IEEE 802.11b 

o

 

Wired: IEEE 802.3, IEEE 802.3u 

 

Wireless transmission rate: 

o

 

11n: up to 150Mbps 

o

 

11g: up to 54Mbps 

o

 

11b: up to 11Mbps 

 

Tracks number: 1-14 

 

Frequency range: 2.4-2.4835GHz 

 

Input power: 5V 

 

Emission power: 12-15 DBM 

 

Interface: WAN, LAN, RS232, DC In, Antenna 

 

Antenna type: external, 6DB 

 

Wi-fi working mode: Client/AP/Router 

 

Wireless MAC address filtering 

 

Wireless security function switch 

 

1

 If a backup battery is installed 

 

Wireless security: 

o

 

WEP encryption: 64/128/152 bit 

o

 

Security mechanism: WPA-PSK/WPA2-PSK, WPA/WPA2  

 

Network management 

o

 

Remote web management 

o

 

Configuration file import/export 

o

 

Web software upgrade 

 

Serial to Ethernet: 

o

 

Maximum transmission rate: 500,000bps 

o

 

TCP/UDP connection: max. connection number>20 

o

 

Serial baud rate: 1200-500,000bps 

 

Frequency bandwidth optional: 20MHz, 40MHz, Automatic 

 

CE compliance 

 

Dimensions: 8.5 X 8.5 X 2.5 cm  

 

Weight: 160g 

 

Operating temperature: -10 to +55 °C 

 

Humidity (max.): 90% R.H., non-condensing 

6

7

3

5

LED

LAN

WAN

RST

DC IN

WFM

FORCE

 Control Panel

1

4

2

8

9

Summary of Contents for WFM500

Page 1: ...rol panel1 and is configured using a web browser For the programming information see the FORCE s Installation guide P N 4410459 Technical specifications Network standard o Wireless IEEE 802 11n IEEE 802 11g IEEE 802 11b o Wired IEEE 802 3 IEEE 802 3u Wireless transmission rate o 11n up to 150Mbps o 11g up to 54Mbps o 11b up to 11Mbps Tracks number 1 14 Frequency range 2 4 2 4835GHz Input power 5V ...

Page 2: ...page and the control panel s Ethernet socket no 8 in the above image 3 Connect the DC plug to the DC In socket no 7 in the above image 4 Connect the two wires on the other end of the DC cable to the detector s voltage terminals the Red wire is connected to the terminal the White wire is connected to the terminal no 9 in the above image and check the LED see below 5 Connect and program the adapter ...

Page 3: ...ких шкафов и на металлических конструкциях Не устанавливайте модуль в непосредственной близости к электропроводке самой контрольной панели и ее периферии Минимально рекомендуемое расстояние от расширителя до данной периферии 3 метра Не устанавливайте модуль вблизи источников тепла и под прямыми солнечными лучами Не устанавливайте модуль в местах повышенной влажности а также избегайте попадания жид...

Page 4: ... operación de 10 a 55 C Humedad Máx 90 R H Sin condensación Contenido del paquete Adaptador WFM Antena Cable CAT5 2m Cable DC 2m Tornillos 4 anclajes Esta guía Consideraciones de montaje e instalación Monte el WFM en una superficie plana donde la señal de Wi Fi sea fuerte No instale el expansor dentro de una carcasa metálica Monte el adaptador al menos a tres metros de distancia de cualquier dispo...

Page 5: ...ס יחסית לחות 90 ללא התעבות ת כ המוצר אריזת ולת מקלט WFM אנטנה כבל CAT7 2 מ כבל DC 2 מ 4 דיבלים ברגים זה מדריך ל הנחיות בחירת ההתקנה מקום המ את מקם בו במקום תאם קליט ת ה Wi fi אופטימלית א מ אתה ם ה את תקין מ תאם מתכתית קופסה בתוך לקופסה מחוץ האנטנה את התקן ה את התקן מ תאם ש לפחות של במרחק לושה קרינה פולט אלקטרוני מכשיר מכל מטר ה את לחשוף אין מ תאם חזק מלאכותי אור או שמש קרני ישיר חום למקור ה את להר...

Page 6: ...свенные убытки возникшие вследствие некорректных действий по установке сопровождению эксплуатации либо связанных с выходом из строя или временной неработоспособностью Оборудования Copyright 2020 PIMA Electronic Systems Ltd All rights reserved E OE Garantía Limitada PIMA Electronic Systems Ltd no garantiza que su Producto no haya sido o sea puesto en riesgo o que no sea evadido o que no sea o haya ...

Page 7: ... 7 ...

Page 8: ... 8 P N 4410469 4410469 Revision A1 XX multi Jul 2020 ...

Reviews: