![Pima HUNTER-PRO RXN-9 User Manual Download Page 1](http://html1.mh-extra.com/html/pima/hunter-pro-rxn-9/hunter-pro-rxn-9_user-manual_1557083001.webp)
PIMA Electronic Systems Ltd. does not represent that its Product may not be compromised
and/or circumvented, or that the Product will prevent any death, personal and/or bodily injury
and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the
Product will in all cases provide adequate warning or protection. The User understands that a
properly installed and maintained equipment may only reduce the risk of events such as
burglary, robbery, and fire without warning, but it is not insurance or a guarantee that such will
not occur or that there will be no death, personal damage and/or damage to property as a
result.
PIMA Electronic Systems Ltd. shall have no liability for any death, personal and/or
bodily injury and/or damage to property or other loss whether direct, indirect, incidental,
consequential or otherwise, based on a claim that the Product failed to function.
Warning:
The user should follow the installation and operation instructions and among other
things test the Product and the whole system at least once a week. For various reasons,
including, but not limited to, changes in environment conditions, electric or electronic
disruptions and tampering, the Product may not perform as expected. The user is advised to
take all necessary precautions for his/her safety and the protection of his/her property.
This document may not be duplicated, circulated, altered, modified, translated, reduced to any
form or otherwise changed; unless PIMA’s prior written consent is granted.
All efforts have been made to ensure that the content of this manual is accurate. Pima retains
the right to modify this manual or any part thereof, from time to time, without serving any prior
notice of such modification.
Please read this manual in its entirety before attempting to program or operate your system.
Should you misunderstand any part of this manual, please contact the supplier or installer of
this system.
Copyright
2005 by PIMA Electronic Systems Ltd. All rights reserved. You can contact us at
PIMA Electronic Systems Ltd.5 Hatzoref Street, Holon 58856, Israelhttp://www.pima-
alarms.com
SAFETY INSTRUCTIONS
Your HUNTER-PRO RSA alarm system has been registered in accordance with EN60950 and
its rules. EN 60950 requires us to advise you the following information:
1. In this alarm system exist hazards of fire and electric shock. To reduce the risk of fire or
electric shock, do not expose this alarm system to rain or moisture. Pay attention:
Telephone cords could be a good conductor for lightings energy.
2. Do not open the door of the alarm system. Dangerous high voltages are present inside of
the enclosure. Refer servicing to qualified personnel only.
3. This alarm system should be used with AC 230V/110V, 50Hz, protected by anti electric
shock breaker. To prevent electric shocks and fire hazards, do NOT use any other power
source.
4. Do not spill liquid of any kind onto the unit. If liquid is accidentally spilled onto the unit,
immediately consult a qualified service.
5. Install this product in a protected location where no one can trip over any line or power cord.
Protect cords from damage or abrasion.
6. Disconnect all sources of power supply before proceeding with the installation. Pay
attention: do not install low voltage wires near by AC power wires they should be separated.
7. Connect the AC transformer output to the terminal block on the control panel as marked.
8. Connect the AC line cord to line power terminals as marked. (GND; N; L)
HUNTER-PRO RSA
Intruder Alarm System
RXN-9 User Guide
PIMA Electronic Systems Ltd.
5 Hatzoref Street, Holon 58856, Israel
℡
+972-3-5587722
+972-3-5500442
http://www.pima-
alarms.com
A
BOUT THIS
M
ANUAL
The symbol:
indicates pressing keypad key(s)
The symbol
:
indicates pressing and holding key(s)
I
NTRODUCTION
First time operation
When the keypad is first connected to power, its circuitry and
LEDs are tested. All LEDs will light in a changing pattern for 2-3
sec and then the keypad will start operating with the HUNTER-
PRO RSA panel.
Each LED corresponds with a different zone (numbers 1 to 9).
The LEDs are OFF when the zones are closed and flash when
the zones are open.
Normal Display
Each LED correspond a zone (numbers 1-9).
Zone LED Display
Status
OFF
Zone is closed
Flashing
Zone is open
ON
Zone caused an alarm
Fault Display
When a fault occurs, the red FAULT LED blinks.
Press & Hold:
to display faults (see table)
The corresponding fault LED will lit as described in the following
table:
LED
No.
Indication Fault
Description
1
BATTERY
*
Low battery
2 AC
*
No voltage from mains
3 PHONE
*
No communication with monitoring
station or, a problem with telephone
line
4 DC
*
Low
voltage
5 ZONE
*
Fault
zone
6
CLOCK
Hour and/or date not correct
7 TAMPER
*
Open
tamper
8 FUSE
*
Detector’s voltage is short
9 BELL
*
External/Internal Bell fault
* These faults should be fixed by a qualified technician/installer.
An error with the present keypad programming or connection
will cause a sequential LED flashing as follows:
LEDs are flashing left-to-right:
The keypad ID should be
reprogrammed
LEDs are flashing right-to-left:
The keypad is disconnected
from the panel