68
Programming the System
Hunter-Pro Series & Captain 8 Installation Guide
6.10.2
The Output Types
In PIMA alarm systems, "Output Types" are detected events that are used for triggering the
physical outputs. Each output can be triggered by only one output type, whereas the same
output type can trigger as much as all the physical outputs.
The following table describes the output types and their triggers.
[NEXT]
Output type
The event that triggers it
-
External Siren
Zone alarm or system fault that are set to trigger the
"External Siren" output type as a response to alarm
X1
Internal Siren
Zone alarm or system fault that are set to trigger the
"Internal Siren" output type as a response to alarm
X2
Burglary
Alarm in a “Burglary” zone
X3
Anti-Mask
Alarm in an “Anti-Mask” zone
X4
Special Burglary 1 Alarm in a “Special Burglary 1” zone
X5
Special Burglary 2
Alarm in a “Special Burglary 2” zone
X6
Burglary - All
Types
Alarm in “Burglary”, “Special Burglary 1” or “Special
Burglary 2” zones
X7
Fire
Alarm in a “Fire” zone
X8
Special Fire
Alarm in a “Special Fire” zone
X9
Panic
Alarm in a “Panic” zone, or pressing the panic key
combination [*]+[#].
X10
Silent Panic
Alarm in a “Silent Panic” zone
X11
Hold-Up (Duress)
Alarm in a “Hold-Up (Duress)” zone, or entering
the “Duress” code
X12
Medical
Alarm in a “Medical” zone
X13
Alarms - All Types
Any alarm
X14
Audio Control
Triggering an audio module: MIC-200 or VU-20N/U
X15
Zone Open
Opening a zone (regardless of the panel status)
X16
Zone Bypassed
Zone is bypassed by a user
X17
Smoke Detector
Power
Resetting smoke/fire detectors
X18
Tamper
Opening a tamper switch (connected via TMPR1/TMPR2
terminals)
X19
Zone tamper/fail
Opening a zone tamper, or a zone failure
X20
Buzzer
Activating the "Buzzer" output type
X21
Armed
Arming the panel to any mode
X22
Installer Program
Entering the Installer code
X23
General Fault
AC, Low battery or Phone line faults occur
X24
Mains Fault
AC fault occurs
X25
Low Battery
Low battery fault occurs
X26
Phone Fault
Phone line fault occurs
X27
GSM Fault
GSM fault occurs
X28
Comm. Fault
Communication fault occurs
X29
Not In Use
-
X30
Door Code
Entering the Door code
Summary of Contents for Hunter-Pro 8144
Page 111: ...Appendix D CAPTAIN 8 Factory Defaults 111 Hunter Pro Series Captain 8 Installation Guide...
Page 112: ...Appendix D CAPTAIN 8 Factory Defaults 112 Hunter Pro Series Captain 8 Installation Guide...
Page 113: ...Appendix D CAPTAIN 8 Factory Defaults 113 Hunter Pro Series Captain 8 Installation Guide...
Page 114: ...Appendix D CAPTAIN 8 Factory Defaults 114 Hunter Pro Series Captain 8 Installation Guide...
Page 115: ...Appendix D CAPTAIN 8 Factory Defaults 115 Hunter Pro Series Captain 8 Installation Guide...