background image

PSSu E S 2AI RTD(-T)

Operating Manual 22017-EN-07

}

Decentralised system PSSuniversal I/O

Summary of Contents for PSSu E S 2AI RTD

Page 1: ...PSSu E S 2AI RTD T Operating Manual 22017 EN 07 Decentralised system PSSuniversal I O...

Page 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Page 3: ...chanisms 12 4 2 2 Functions 12 4 3 Configuration 13 4 3 1 Measuring ranges 13 4 3 2 Connection type 14 4 3 3 Range monitoring 14 4 3 4 Offset for the 2 wire measurement 14 4 3 5 Digital filter 15 4 3...

Page 4: ...ines 27 6 1 1 Mechanical connection of the base modules 27 6 2 Terminal configuration 29 6 3 Connecting the module 31 Section 7 Operation 33 7 1 Messages 33 7 2 Display elements 33 7 2 1 Display eleme...

Page 5: ...This documentation is intended for instruction and should be retained for future reference 1 1 2 Terminology System environment A and B The PSSu system can be used in two different system environments...

Page 6: ...tuation that could lead to serious injury and death and indicates preventive measures that can be taken CAUTION This refers to a hazard that can lead to a less serious or minor injury plus material da...

Page 7: ...s function Details of the base modules that can be used are available in the chapter entitled Intended Use 2 2 Module features The product has the following features Analogue ST inputs 2 Type of inpu...

Page 8: ...RTD 11 R0 12 R0 13 C 14 R1 15 R1 16 C 21 RL0 22 RL0 23 C 24 RL1 25 RL1 26 C Err 21 11 22 12 23 13 24 14 26 16 25 15 1 3 8 7 4 5 6 12 2 13 A B 9 11 10 Legend A Electronic module B Base module 1 LED for...

Page 9: ...ection level 5 10 Connection level 6 11 Square mounting holes connection levels 1 2 3 and 4 With screw to loosen tighten the screw terminal on base modules with screw termin als With mechanism to oper...

Page 10: ...ntal requirements see Technical Details Intended use includes making the electrical installation EMC compliant Please refer to the guidelines stated in the PSSuniversal Installation Manual The module...

Page 11: ...personnel who Are familiar with the basic regulations concerning health and safety accident preven tion Have read and understood the information provided in this description under Safety And have a g...

Page 12: ...ror 4 2 2 Functions The module supply provides the module with voltage The periphery supply provides the analogue section with voltage The input signals are read in and converted into digital signals...

Page 13: ...is possible to configure all the values Via the USB port of the head module using the PSSuniversal Configurator All the values can be configured using the PSSuniversal Assistant Any configuration via...

Page 14: ...assignment in system environment B 21 The module behaves as follows irrespective of the range monitoring configuration If the value falls below the range the temperature value stops The temperature v...

Page 15: ...ed and return line in 1 16 Ohm under 2 wire measurement offset When you have established the measuring line resistance using the module re se lect the required sensor under Measuring range 4 3 5 Digit...

Page 16: ...ng is a multi stage process to adapt the values from the AD converter The straight path in the diagram indicates the default configuration Raw value output Man scaling active Hardware calibration Manu...

Page 17: ...x the signal after manufacturer scaling y offset b1 and gain a1 is a linear equation as follows y a1 256D x b1 or y a1 100H x b1 The term a1 256D corresponds to the amplification factor With the stat...

Page 18: ...d magnitude representation and two s complement representation The values in the following tables apply with default scal ing Analogue value and typical digital value with a measuring range of 100 C 1...

Page 19: ...nt 2 wire measurement offset 0 32767D 0 Resolution in 1 16 Ohm Manufacturer scaling Activated TRUE Manufacturer scaling offset 32768 32767D 0 Manufacturer scaling gain 32768 32767D 160D Amplification...

Page 20: ...for the status byte where this has been con figured for the input All the status bytes are displayed first in the PII followed by the input data Configuration Standard bus system Input data ST PII ST...

Page 21: ...r equal to the lower limit value 1 Value below the lower limit value 1 0 Input value below or equal to the upper limit value 1 Value above the upper limit value 2 5 7 0 Reserved 1 Reserved 6 0 No modu...

Page 22: ...tatic discharge Electrostatic discharge can damage components Ensure against discharge before touching the product e g by touching an earthed conductive sur face or by wearing an earthed armband 5 1 1...

Page 23: ...base modules with cage clamp terminals All contacts should be protected from contamination The mechanics of the base modules are designed for 50 plug in out cycles Procedure We recommend that you wire...

Page 24: ...may only be inserted and removed when the load is switched off Unforeseeable error reactions may be triggered if modules are inserted and removed under load When an electronic module is plugged into...

Page 25: ...al PSSu E S 2AI RTD T 22017 EN 07 25 5 3 1 Inserting an electronic module Procedure The electronic module must audibly lock into position 1 Mark the electronic module using the labelling strips 2 Sche...

Page 26: ...ing operation The configuration data is re tained when a module is changed Effects System environment A In the event of a potential FS communication error the FS section of the PSSu sys tem and all re...

Page 27: ...ect the mounting rail to the functional earth via an earthing terminal In environments with strong EMC interference base modules without a C rail provide better protection if the shield is connected U...

Page 28: ...seated 21 11 1 3 2 4 5 6 Please note The minimum cable cross section for field connection terminals on the base modules is 0 14 mm2 AWG26 The maximum cable cross section for field connection terminal...

Page 29: ...EN 60947 1 such as the PZ 1 5 or PZ 6 5 from Weidm ller for example Maximum torque setting 0 8 Nm Use copper wiring 6 2 Terminal configuration Base module Terminal configuration Screw terminals PSSu...

Page 30: ...terminals PSSu BP C 1 12 C PSSu BP C 1 12 C T With C rail 11 Input R0 21 Input RL0 12 Input R0 22 Input RL0 13 23 C rail supply shield connection 13 23 16 26 linked within the base module 14 Input R1...

Page 31: ...2 wire measurement 21 11 22 12 23 13 24 14 26 16 25 15 R0 R0 R1 R1 RL0 RL0 RL1 RL1 J J 21 11 22 12 23 13 24 14 26 16 25 15 R0 R0 R1 R1 C C RL0 RL0 RL1 RL1 C C J J 3 wire measurement 21 11 22 12 23 13...

Page 32: ...RTD T 22017 EN 07 32 Input circuit Without C rail With C rail Connection for 4 wire sensor 21 11 22 12 23 13 24 14 26 16 25 15 R0 R0 R1 R1 RL0 RL0 RL1 RL1 J J 21 11 22 12 23 13 24 14 26 16 25 15 R0 R...

Page 33: ...error Incorrect module type configured The configured hardware registry does not match the actual hard ware registry ST communication error Error during ST communication Change faulty module Bus termi...

Page 34: ...input is assigned an LED for displaying the input status LEDs I0 and I1 11 21 I0 I1 Err I0 I1 Err LED Meaning Designa tion Colour Status Signal Input Ter minal I0 No sig nal de tected I0 Input 1 11 1...

Page 35: ...lectrical data 312490 314490 Internal supply voltage module supply Module s power consumption 0 63 W 0 63 W Periphery s supply voltage peri phery supply Voltage range 16 8 30 0 V 16 8 30 0 V Module s...

Page 36: ...meas urement with attenuation Attenuation 90 dB 60 Hz 90 dB 60 Hz Filter time 103 ms 103 ms Attenuation 80 dB 50 Hz 80 dB 50 Hz Filter time 122 ms 122 ms Attenuation 65 dB 50 Hz 60 Hz 65 dB 50 Hz 60 H...

Page 37: ...d EN 60068 2 30 EN 60068 2 78 EN 60068 2 30 EN 60068 2 78 Humidity 93 r h at 40 C 93 r h at 40 C Condensation during operation Not permitted Short term EMC EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61...

Page 38: ...60529 Mounting area e g control cab inet IP54 IP54 Housing IP20 IP20 Mechanical data 312490 314490 Material Bottom PC PC Front PC PC Coding PA PA Dimensions Height 76 0 mm 76 0 mm Width 12 6 mm 12 6 m...

Page 39: ...s 312 618 PSSu BP 1 12 S T Base module without C rail with screw terminals T type 314 618 PSSu BP 1 12 C Base module without C rail with cage clamp terminals 312 619 PSSu BP 1 12 C T Base module witho...

Page 40: ...T p ThE SPIrIT Of SAfETY are registered and protected trademarks of Pilz Gmbh Co KG in some countries We would point out that product features may vary from the details stated in this document dependi...