Commissioning
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 73
Overrun
Height of the protected field
(O 6 mm)
Colour of protected field
(see diagram)
4 mm
10 mm
Purple
2 mm
8 mm
(minimum protected field)
Red
}
You can switch to the adjustment image without guide frame by pressing <ENTER>
again.
}
Exit the adjustment using the <ESC> key.
The transmitter and receiver are now mechanically aligned.
NOTICE
After you have aligned the transmitter and receiver you will still need to
carry out the step for "Adjustment during tool change" (see section entitled
"Adjustment during tool change").
7.2.2
Adjustment template with bracket
An adjustment template screwed to a suitable bracket is also available as an accessory.
This bracket is not supplied with the system.
}
Fasten the template to the bracket using half length taper-grooved dowel pins and cylin-
der head bolts (see illustration).
10
45
65
Ø 3
+0,1
Ø 3,4
Ø 3,4
Ø 3
+0,1
1
3
2
Fig.: Adjustment template to attach to bracket
}
1: Ø 3 mm DIN 1472 half length taper-grooved dowel pin
}
2: M3 x 10 cylinder head bolts
}
3: Ø 3 mm DIN 1472 half length taper-grooved dowel pin