Function description
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 48
7
Status
Press is at bottom dead
centre
v = 0
BDC
Foot switch
1
System-Init
0
OSSD
0
Protected field
Interrupted
Mute 1/2
0
Dynamic muting
Inactive
8
Status
Upward movement
Advance measuring field
is cleared
v < 0
Foot switch
1
Generally, the press
travels up automatically,
the operator can release
the foot switch.
System-Init
1
OSSD
1 or 0
Protected field
Free or interrupted
Mute 1/2
0 - > 1
Dynamic muting
Inactive
Continue with step 1
4.7.3
System cycle for back gauge press stroke
Inputs on the PSENvip receiver:
}
Protected field mode 1 = 1
}
Protected field mode 2 = 0
}
Acknowledgement of reduced protected field = Press pushbutton and then release
The system cycle is the same as for box bending. Please note that with back gauge protec-
ted field mode, the rear segments of the protected field are blanked.