Function description
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 41
4.6
Operating modes during commissioning
The PSENvip has the following options for commissioning:
}
Press brake setup mode
}
Adjustment during initial commissioning
}
Adjustment during tool change
4.6.1
Press brake setup mode
Setup mode must be activated when work is to be carried out on the press brake. The
transmitter and receiver must be switched off. The display is switched on. By switching off
the transmitter's light source the tool setter has visual communication that there is no safety
function via the protected field. The
OSSD
LED on the receiver lights up red.
The input Power Off = 1 switches off the transmitter's light source.
4.6.2
Adjustment during initial commissioning
The transmitter and receiver are aligned to each other during initial commissioning. The
vertical and horizontal alignment is performed using templates and is displayed on the re-
ceiver.
In this operating mode
}
The protected field is inactive.
}
The OSSDs are switched off.
}
There is no protection via the PSENvip.
INFORMATION
Details of the adjustments made during initial commissioning are described
in Chapter 7, "Commissioning", section entitled "Initial commissioning".
4.6.3
Adjustment during tool change
The tool is assigned to a tool class in "Tool change" operating mode. Once the tool data
has been saved it is downloaded to the safety system.
The adjustment line is automatically tracked to the tip of the tool. The tracking is shown on
the display. This makes it easier to adjust to the different tool sizes.
INFORMATION
Generally you should not have to mechanically realign the transmitter and
receiver during a tool change.
In this operating mode
}
The protected field is inactive.
}
The OSSDs are switched off.
}
There is no protection via the PSENvip.