PSEN opII4H Series
Operating Manual PSEN opII4H Series
1003501-EN-02
44
Where standards are undated, the 2015-12 latest editions shall apply.
Technical details Order no. 632063-632065
General
632063
632064
632065
Approvals
CE, TÜV
CE, TÜV
CE, TÜV
ESPE type
4
4
4
Sensor's mode of opera-
tion
Infrared
Infrared
Infrared
Height of protected field
600 mm
750 mm
900 mm
Resolution
Operating range
0,2 - 18 m
0,2 - 18 m
0,2 - 18 m
Detection capability
30 mm
30 mm
30 mm
Electrical data
632063
632064
632065
Supply voltage
Voltage
24 V
24 V
24 V
Kind
DC
DC
DC
Voltage tolerance
-25 %/+20 %
-25 %/+20 %
-25 %/+20 %
Residual ripple DC
5 %
5 %
5 %
Max. power consumption
receiver
12 W
12 W
12 W
Max. power consumption
transmitter
7,2 W
7,2 W
7,2 W
Max. inductive load per
output
1 H
1 H
1 H
Optical data
632063
632064
632065
Opening angle
-2,5 - 2,5 deg
-2,5 - 2,5 deg
-2,5 - 2,5 deg
Used wavelength range
850 nm
850 nm
850 nm
Inputs
632063
632064
632065
Max. overall line capacit-
ance Clmax
40 nF
40 nF
40 nF
Semiconductor outputs 632063
632064
632065
OSSD safety outputs
2
2
2
Switching current per out-
put
100 mA
100 mA
100 mA
Times
632063
632064
632065
Test pulse duration, safety
outputs
300 µs
300 µs
300 µs
Supply interruption before
de-energisation
600 µs
600 µs
600 µs
Response time t1
14 ms
15 ms
15 ms
Environmental data
632063
632064
632065
Ambient temperature
Temperature range
-10 - 60 °C
-10 - 60 °C
-10 - 60 °C
Storage temperature
Temperature range
-25 - 70 °C
-25 - 70 °C
-25 - 70 °C